Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
10658823 | 3 - Design Control Reference | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 000884813 | A047B0 | 00209 | X | 1 | A | P | A | 29 Dec 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | A | TX | D | 10658823 | 18876 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 3 Dec 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BD | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 1.000 INCHES NOMINAL |
ADAQ | Body Length | 2.800 INCHES NOMINAL |
ADAT | Body Width | 5.510 INCHES NOMINAL |
CRBC | Discrimination At Specified Frequencies Per Function In Decibels | 3.0 MINIMUM BLANK AND 70.0 MAXIMUM BLANK |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.300 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.310 INCHES NOMINAL |
CBBL | Features Provided | FUNGUS RESISTANT AND MOUNTING BRACKET |
CRBB | Frequency Band Width Per Function | 1.35 GIGAHERTZ BLANK AND 1.45 GIGAHERTZ BLANK |
CQDW | Functional Terminal Type And Quantity | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION1 CONNECTOR, PLUG OUTPUT 2ND FUNCTION |
AHCH | Average Power Rating Per Function | 10.0 WATTS BLANK |
CQRG | Body Material | ALUMINUM |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
AKEJ | Mounting Facility Screw Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.138 INCHES |
AFGA | Operating Temp Range | -29.0 TO 52.0 DEG CELSIUS |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE BLANK |
CQFC | Specified Frequencies Of Discrimination Per Function | 1.115 GIGAHERTZ BLANK AND 1.35 GIGAHERTZ BLANK AND 1.45 GIGAHERTZ BLANK AND 1.685 GIGAHERTZ BLANK |
AECR | Vibration Resistance Range In Hertz | +10.0 TO 500.0 |
AKNA | Inclosure Type | HERMETICALLY SEALED |
CQDR | Insertion Loss At Reference Frequency Per Function In Decibels | 1.0 BLANK |
AHAS | Load Impedance Per Function | 50.0 OHMS BLANK |
AHAJ | Reference Frequency Per Function | 100.0 MEGAHERTZ BLANK |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS BLANK |
ABHP | Overall Length | 4.370 INCHES NOMINAL |
FEAT | Special Features | ONE SMA FEMALE TYPE INPUT CONNECTOR,ONE SMA MALE TYPE OUTPUT CONNECTOR |
CRBN | Voltage Standing Wave Ratio Frequency Limits Per Function | 1.35 GIGAHERTZ BLANK AND 1.45 GIGAHERTZ BLANK |
AHBZ | Voltage Standing Wave Ratio Per Function | 1.5 BLANK |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |