Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
JN174163B | 3 - Design Control Reference | 2 - Production Item | SPRAGUE ELECTRIC CO | 56289 | ![]() |
9638-101-9000 | 3 - Design Control Reference | 9 - No Longer Used | MURATA ERIE NORTH AMERICA INC DIVOF | 12294 | ![]() |
690497-2 | 5 - Replaced / Discontinued | 9 - No Longer Used | BAE SYSTEMS INFORMATION AND | 80249 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 002423480 | A047B0 | 00765 | X | 1 | A | P | A | 30 Dec 1971 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 2 | ME | D | JN174163B | 56289 | ![]() | ||||
3 | 3 | 9 | 2 | ME | D | 9638-101-9000 | 12294 | ![]() | ||||
3 | 5 | 9 | 2 | ME | B | 690497-2 | 80249 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
Engineering Data Support Center, Hill AFB, UT 84056-5609
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 7 May 1994 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | J | 593 | Z | Z | A | H | Z | J | 069100 | F | 21275 | FILTERS-FILTERS-NOI-SUB6 |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
100.2
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | X | D3 | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAQ | Body Length | 2.010 INCHES NOMINAL |
ADAT | Body Width | 2.010 INCHES NOMINAL |
CQDW | Functional Terminal Type And Quantity | 4 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | Functional Terminal Type And Quantity | 4 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
AHBE | Maximum Voltage Drop Per Function | 1.0 VOLTS AC 1ST RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 1.0 VOLTS AC 3RD RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 1.0 VOLTS AC 4TH RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 1.0 VOLTS AC 2ND RADIO INTERFERENCE |
AXHR | Mounting Facility Type And Quantity | 1 THREADED HOLE |
AKEJ | Mounting Facility Screw Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.112 INCHES |
AHBC | Operating Current Rating Per Function In Amps | 0.8 2ND RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 3RD RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 4TH RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 1ST RADIO INTERFERENCE |
AFGA | Operating Temp Range | -55.0/+95.0 DEG CELSIUS |
CQGC | Operating Voltage Rating And Type Per Function | 130.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 130.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 130.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 130.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AKNA | Inclosure Type | HERMETICALLY SEALED |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 1ST RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 3RD RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 4TH RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 2ND RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
ABKW | Overall Height | 1.125 INCHES NOMINAL |
ABHP | Overall Length | 2.504 INCHES NOMINAL |
AECR | Vibration Resistance Range In Hertz | +10.0/+2000.0 |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |