Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
554-5220-004 | 3 - Design Control Reference | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 009696382 | A047B0 | 00765 | X | 4 | 3 | A | P | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YD01 | 1 Aug 2016 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 21 Nov 1990 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
658 | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 42 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | DA | BG | X | D1 | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
A-A-1249, paper, tissue
A-A-1898, Grade II, water resistant cellulosic cushioning
As required to protect the item or elements of the package
PPP-B-566 or PPP-B-676, folding or setup box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQRG | Body Material | METAL |
CQDW | Functional Terminal Type And Quantity | 17 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | Functional Terminal Type And Quantity | 17 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED HOLE |
AKEJ | Mounting Facility Screw Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.112 INCHES |
AFGA | Operating Temp Range | -55.0/+85.0 DEG CELSIUS |
AKNA | Inclosure Type | ENCASED |
AHAS | Load Impedance Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 6TH RADIO INTERFERENCE |