5915-00-975-9917

FILTER,RADIO FREQUENCY INTERFERENCE


5915-00-975-9917 (5915009759917, 009759917)
Part Numbers (2 listings): 905121-1 | GF-6904 |
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 5 Oct 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-00-975-9917 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
905121-13 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
GF-69045 - Replaced / Discontinued9 - No Longer UsedGENISCO FILTER CORP.  07294    CAGE 07294  
GF-69045 - Replaced / Discontinued9 - No Longer UsedSPECTRUM CONTROL INC.  13050    CAGE 13050  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5915-00-975-9917 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915009759917A047B000765X1APU5 Oct 1966
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

009759917

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-00-975-9917

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

5 Oct 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5915-00-975-9917 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG011 Apr 1991
DGX1DTX13RTX1 Jun 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

R

Acquisition Method Suffix Code (AMSC_2876)


The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

TX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG C - REFERENCE NUMBER | NSN 5915-00-975-9917 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3324TAD905121-1  06481   CAGE/06481
4595TXBGF-6904  07294   CAGE/07294
595TXGF-6904  13050   CAGE/13050
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

TA

Reference Number Action Activity Code (RNAAC_2900)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-00-975-9917 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX028 Mar 1968
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Mar 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-00-975-9917 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP061990X58500ELECTRICAL-EQUIP-FILTERS
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061990

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

58500

Uniform Freight Classification (UFC_CD_MODF_3040)

ELECTRICAL-EQUIP-FILTERS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5915-00-975-9917 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-00-975-9917 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length1.510 INCHES NOMINAL
CQRGBody MaterialMETAL
ADATBody Width1.485 INCHES MINIMUM AND 1.515 INCHES MAXIMUM
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length1.750 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width1.250 INCHES NOMINAL
AHCJFull Load Insertion Loss Frequencies In Megahertz0.1 AND 0.5 AND 1.0 AND 5.0 AND 10.0 AND 20.0
AHCKFull Load Minimum Insertion Loss At Specified Frequency In Decibels20.0 AND 50.0 AND 60.0 AND 80.0 AND 70.0 AND 60.0
CQDWFunctional Terminal Type And Quantity3 TAB, SOLDER LUG INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
AHCGMaximum Temp Rise30.0 DEG CELSIUS
AHBEMaximum Voltage Drop Per Function400.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE
AHBEMaximum Voltage Drop Per Function400.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE
AXHRMounting Facility Type And Quantity12 TERMINAL
AXHRMounting Facility Type And Quantity3 UNTHREADED HOLE
AHBCOperating Current Rating Per Function In Amps0.75 2ND RADIO INTERFERENCE
AHBCOperating Current Rating Per Function In Amps0.75 3RD RADIO INTERFERENCE
AHBCOperating Current Rating Per Function In Amps0.75 1ST RADIO INTERFERENCE
AFGAOperating Temp Range-55.0/+95.0 DEG CELSIUS
CQGCOperating Voltage Rating And Type Per Function28.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOperating Voltage Rating And Type Per Function28.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOperating Voltage Rating And Type Per Function28.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBTOutput Terminal IdentificationAAAS-60T-L4X
AHBSOutput Terminal Manufacturer Code20093
AKNAInclosure TypeHERMETICALLY SEALED
AHBPInput Terminal IdentificationAAAS-60T-L4X
AHBNInput Terminal Manufacturer Code20093
AHASLoad Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE
AHASLoad Impedance Per Function50.0 OHMS 3RD RADIO INTERFERENCE
AHASLoad Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz420.0 3RD RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz420.0 1ST RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz420.0 2ND RADIO INTERFERENCE
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 OHMS 3RD RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE
ABKWOverall Height0.590 INCHES MAXIMUM
ABHPOverall Length1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
ABMKOverall Width1.665 INCHES MAXIMUM
PKWTUnpackaged Unit Weight5.000 OUNCES
AEBVUnthreaded Mounting Hole Diameter0.141 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
AECRVibration Resistance Range In Hertz+10.0/+500.0
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES


Back to Top