5915-00-992-0314

FILTER,RADIO FREQUENCY INTERFERENCE


5915-00-992-0314 (5915009920314, 009920314)
Part Numbers (7 listings): FA5349-2 | RF01177 | NF10796 | FC-864 | F-17172 | 0N008443-2 | RF1177 |
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT:

HMIC: Y

Date Created: 1 Jan 1962

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-00-992-0314 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
FA5349-23 - Design Control Reference2 - Production ItemEMS DEVELOPMENT CORPORATION  13619    CAGE 13619  
RF011775 - Replaced / Discontinued2 - Production ItemEMS DEVELOPMENT CORPORATION  13619    CAGE 13619  
NF107965 - Replaced / Discontinued2 - Production ItemCORNELL-DUBILIER ELECTRONICS  93790    CAGE 93790  
FC-8645 - Replaced / Discontinued2 - Production ItemFIL-COIL FC INC.  56528      
F-171725 - Replaced / Discontinued2 - Production ItemLCR ELECTRONICS, INC.  0AM43      
0N008443-25 - Replaced / Discontinued2 - Production ItemNATIONAL SECURITY AGENCY  98230    CAGE 98230  
FA5349-25 - Replaced / Discontinued9 - No Longer UsedFILTRON CO INC  81831      
RF11775 - Replaced / Discontinued9 - No Longer UsedEMS DEVELOPMENT CORPORATION  13619    CAGE 13619  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5915-00-992-0314 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915009920314A047B000765X1AYU1 Jan 1962
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

009920314

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-00-992-0314

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

Y

Hazardous Material Indicator Code (HMIC_0865)


Indicates information is in the Hazardous Materials Information Resource System (HMIRS).

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5915-00-992-0314 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZR011 Jul 1997
ZW011 Dec 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5915-00-992-0314 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZFA5349-2  13619   CAGE/13619
525ZZRF01177  13619   CAGE/13619
52ATXFC-864  56528  
526TXNF10796  93790   CAGE/93790
526TX0N008443-2  98230   CAGE/98230
525TXF-17172  0AM43  
595TXRF1177  13619   CAGE/13619
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-00-992-0314 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX013 Aug 1994
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Aug 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-00-992-0314 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
72DZ9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5915-00-992-0314 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5915-00-992-0314 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP421AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXDO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

42

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Container, watervaporproof bag, sealed, container

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-00-992-0314 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height1.391 INCHES MAXIMUM
ADAQBody Length2.875 INCHES NOMINAL
ADATBody Width1.500 INCHES MAXIMUM
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length3.312 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width1.000 INCHES NOMINAL
CQDWFunctional Terminal Type And Quantity1 TAB, SOLDER LUG INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
AHBEMaximum Voltage Drop Per Function500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE
AHBEMaximum Voltage Drop Per Function500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE
AXHRMounting Facility Type And Quantity4 CAPTIVE SCREWS
AKEJMounting Facility Screw Thread Series DesignatorUNC
CQJXNominal Thread Size0.112 INCHES
AHBCOperating Current Rating Per Function In Amps2.0 1ST RADIO INTERFERENCE
AHBCOperating Current Rating Per Function In Amps2.0 2ND RADIO INTERFERENCE
AFGAOperating Temp Range-55.0/+85.0 DEG CELSIUS
CQGCOperating Voltage Rating And Type Per Function253.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOperating Voltage Rating And Type Per Function253.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AKNAInclosure TypeENCASED
AHASLoad Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE
AHASLoad Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz60.0 1ST RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz60.0 2ND RADIO INTERFERENCE
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE
ABHPOverall Length3.750 INCHES NOMINAL
AECRVibration Resistance Range In Hertz+10.0/+500.0
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Back to Top
Back to Top