Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
GF-6902 | 3 - Design Control Reference | 9 - No Longer Used | SPECTRUM CONTROL INC. | 13050 | ![]() |
GF-6902 | 5 - Replaced / Discontinued | 9 - No Longer Used | GENISCO FILTER CORP. | 07294 | ![]() |
905124-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NORTHROP GRUMMAN GUIDANCE AND | 06481 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 009932797 | A047B0 | 00765 | X | 1 | A | P | U | 28 Mar 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 5 | TX | GF-6902 | 13050 | ![]() | ||||||
4 | 5 | 9 | 5 | TX | B | GF-6902 | 07294 | ![]() | ||||
3 | 7 | 2 | 1 | TX | D | 905124-1 | 06481 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 28 Mar 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
M | P | 10 | 1 | AAA | 0.3 lbs | 0.009 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | BG | X | D1 | DO | 00 | E | Q | U |
Manufacturer/Contractor (This code is restricted to DLA LOGISTICS INFORMATION SERVICE input only.)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
A-A-1898, Grade II, water resistant cellulosic cushioning
As required to protect the item or elements of the package
PPP-B-566 or PPP-B-676, folding or setup box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 0.500 INCHES NOMINAL |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
CQRG | Body Material | METAL |
CRST | Body Surface Treatment | TIN |
ADAT | Body Width | 1.440 INCHES NOMINAL |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.625 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.062 INCHES NOMINAL |
AHCJ | Full Load Insertion Loss Frequencies In Megahertz | 0.3 AND 1.0 AND 2.0 AND 5.0 AND 10.0 AND 20.0 |
AHCK | Full Load Minimum Insertion Loss At Specified Frequency In Decibels | 10.0 AND 30.0 AND 45.0 AND 70.0 AND 50.0 AND 30.0 |
CQDW | Functional Terminal Type And Quantity | 6 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | Functional Terminal Type And Quantity | 6 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
AHCG | Maximum Temp Rise | 30.0 DEG CELSIUS |
AHBE | Maximum Voltage Drop Per Function | 300.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 300.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 300.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 300.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 300.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 300.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
AKEJ | Mounting Facility Screw Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.112 INCHES |
AHBC | Operating Current Rating Per Function In Amps | 0.8 1ST RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 2ND RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 3RD RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 4TH RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 5TH RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 0.8 6TH RADIO INTERFERENCE |
AFGA | Operating Temp Range | -55.0/+95.0 DEG CELSIUS |
CQGC | Operating Voltage Rating And Type Per Function | 100.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 100.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 100.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 100.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 100.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 100.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBT | Output Terminal Identification | AAAS-60T-L4X |
AHBS | Output Terminal Manufacturer Code | 20093 |
AKNA | Inclosure Type | HERMETICALLY SEALED |
AHBP | Input Terminal Identification | AAAS-60T-L4X |
AHBN | Input Terminal Manufacturer Code | 20093 |
AHAS | Load Impedance Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 6TH RADIO INTERFERENCE |
ABKW | Overall Height | 0.650 INCHES NOMINAL |
PKWT | Unpackaged Unit Weight | 6.000 OUNCES |
AECR | Vibration Resistance Range In Hertz | +10.0/+500.0 |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
TEST | Test Data Document | 06481-905124-1 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |