5915-01-208-0657

FILTER,RADIO FREQUENCY INTERFERENCE


5915-01-208-0657 (5915012080657, 012080657)
Part Numbers (3 listings): 3593532-1 | E-1975 | RF10364 |
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 8 May 1985

Unit Weight: 8.0 lbs

Unit Size: None

Unit Pack Cube: 0.291 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-01-208-0657 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
3593532-13 - Design Control Reference2 - Production ItemHONEYWELL INTL INC  55974    CAGE 55974  
E-19755 - Replaced / Discontinued2 - Production ItemLINDGREN RF ENCLOSURES INC  23160      
RF103645 - Replaced / Discontinued2 - Production ItemEMS DEVELOPMENT CORPORATION  13619    CAGE 13619  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5915-01-208-0657 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915012080657A047B000765X1APA8 May 1985
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

012080657

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-01-208-0657

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

8 May 1985

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5915-01-208-0657 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
DGX1DTX11CTX1 Jul 2005
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

TX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG C - REFERENCE NUMBER | NSN 5915-01-208-0657 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ATX3593532-1  55974   CAGE/55974
525TXRF10364  13619   CAGE/13619
525TXE-1975  23160  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-01-208-0657 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX023 Aug 1989
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

23 Aug 1989

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-01-208-0657 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TH72DZ9AHZP061990X58500ELECTRICAL-EQUIP-FILTERS
Code Definitions

TH

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43215

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061990

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

58500

Uniform Freight Classification (UFC_CD_MODF_3040)

ELECTRICAL-EQUIP-FILTERS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5915-01-208-0657 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5915-01-208-0657 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA8.0 lbs0.291 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXECDO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

8.0 lbs

Unit Pack Weight (UP_WT_5153)

0.291 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

EC

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-01-208-0657 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height3.000 INCHES NOMINAL
ADAQBody Length6.500 INCHES NOMINAL
CQRGBody MaterialMETAL
ADATBody Width4.000 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length5.500 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width3.000 INCHES NOMINAL
CQDWFunctional Terminal Type And Quantity1 THREADED STUD GROUND 3RD FUNCTION
CQDWFunctional Terminal Type And Quantity4 WIRE LEAD INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity4 WIRE LEAD OUTPUT 2ND FUNCTION
AHBEMaximum Voltage Drop Per Function500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE AND 500.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMaximum Voltage Drop Per Function500.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE AND 500.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMaximum Voltage Drop Per Function500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE AND 500.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMaximum Voltage Drop Per Function500.0 MILLIVOLTS AC 4TH RADIO INTERFERENCE AND 500.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHCGMaximum Temp Rise25.0 DEG CELSIUS
AKEJMounting Facility Screw Thread Series DesignatorUNF
AXHRMounting Facility Type And Quantity4 THREADED HOLE ALL FUNCTIONS
CQJXNominal Thread Size0.190 INCHES
AHBCOperating Current Rating Per Function In Amps10.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOperating Current Rating Per Function In Amps10.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOperating Current Rating Per Function In Amps10.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOperating Current Rating Per Function In Amps10.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AFGAOperating Temp Range-55.0 TO 85.0 DEG CELSIUS
CQGCOperating Voltage Rating And Type Per Function130.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOperating Voltage Rating And Type Per Function130.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOperating Voltage Rating And Type Per Function130.0 VOLTS AC 3RD RADIO INTERFERENCE AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOperating Voltage Rating And Type Per Function130.0 VOLTS AC 4TH RADIO INTERFERENCE AND 400.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AKNAInclosure TypeHERMETICALLY SEALED
AHASLoad Impedance Per Function5.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLoad Impedance Per Function5.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLoad Impedance Per Function5.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLoad Impedance Per Function5.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPower Line Frequency Rating Per Function In Hertz440.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPower Line Frequency Rating Per Function In Hertz440.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPower Line Frequency Rating Per Function In Hertz440.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPower Line Frequency Rating Per Function In Hertz440.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPrincipal Circuitry Type Per FunctionCAPACITANCE-INDUCTANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPrincipal Circuitry Type Per FunctionCAPACITANCE-INDUCTANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPrincipal Circuitry Type Per FunctionCAPACITANCE-INDUCTANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPrincipal Circuitry Type Per FunctionCAPACITANCE-INDUCTANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSource Impedance Rating Per Function5.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSource Impedance Rating Per Function5.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSource Impedance Rating Per Function5.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSource Impedance Rating Per Function5.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
ABHPOverall Length8.750 INCHES NOMINAL
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Back to Top