5915-01-219-8963

FILTER,RADIO FREQUENCY INTERFERENCE


5915-01-219-8963 (5915012198963, 012198963)
Part Numbers (3 listings): 241-0745-020 | 241-0745-00 | 036-0023 |
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 4 Nov 1985

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-01-219-8963 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
241-0745-0203 - Design Control Reference2 - Production ItemROCKWELL COLLINS, INC.  13499    CAGE 13499  
241-0745-005 - Replaced / Discontinued2 - Production ItemSPECTRUM CONTROL, INC.  0LSP2    CAGE 0LSP2  
036-00235 - Replaced / Discontinued2 - Production ItemLEIGHTNER ELECTRONICS, INC  31740      
241-0745-005 - Replaced / Discontinued9 - No Longer UsedSPECTRUM CONTROL, INC.  33095    CAGE 33095  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5915-01-219-8963 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915012198963A047B000765X1APA4 Nov 1985
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

012198963

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-01-219-8963

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

4 Nov 1985

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5915-01-219-8963 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Feb 1994
ZN011 Feb 1999
ZF011 Apr 2000
ZB011 May 2003
ZU011 Jul 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5915-01-219-8963 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ATX241-0745-020  13499   CAGE/13499
525TX036-0023  31740  
525ZZ241-0745-00  0LSP2   CAGE/0LSP2
596TX241-0745-00  33095   CAGE/33095
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-01-219-8963 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX023 Aug 1989
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

23 Aug 1989

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-01-219-8963 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TH
Code Definitions

TH

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43215

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5915-01-219-8963 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XQQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-01-219-8963 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item Identification5895-00-222-4224 COMMUNICATION S
ADAUBody Height1.400 INCHES MAXIMUM
ADAQBody Length3.000 INCHES NOMINAL
ADATBody Width1.590 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.285 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width1.156 INCHES NOMINAL
CQDWFunctional Terminal Type And Quantity2 TAB, SOLDER LUG INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
CRDCMaximum Dielectric Withstanding Dc Voltage600.0 VOLTS AT SEA LEVEL
AHCGMaximum Temp Rise25.0 DEG CELSIUS
AKEJMounting Facility Screw Thread Series DesignatorUNC
AXHRMounting Facility Type And Quantity4 THREADED HOLE 1ST FUNCTION
CQJXNominal Thread Size0.112 INCHES
AHBCOperating Current Rating Per Function In Amps2.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOperating Current Rating Per Function In Amps2.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AFGAOperating Temp Range-55.0 TO 125.0 DEG CELSIUS
CQGCOperating Voltage Rating And Type Per Function280.0 VOLTS AC 1ST RADIO INTERFERENCE AND 600.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOperating Voltage Rating And Type Per Function280.0 VOLTS AC 2ND RADIO INTERFERENCE AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
AKNAInclosure TypeHERMETICALLY SEALED
AHASLoad Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLoad Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPower Line Frequency Rating Per Function In Hertz440.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPower Line Frequency Rating Per Function In Hertz440.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSource Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSource Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
ABKWOverall Height1.780 INCHES NOMINAL
AECRVibration Resistance Range In Hertz+10.0 TO 2000.0
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Back to Top