5915-01-285-1090

FILTER,BAND PASS


5915-01-285-1090 (5915012851090, 012851090)
Part Number (1 listing): 1555
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 7 Sep 1988

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-01-285-1090 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
15553 - Design Control Reference2 - Production ItemPIEZO TECHNOLOGY, INC.  25120      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5915-01-285-1090 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915012851090A047B000209X1APA7 Sep 1988
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

012851090

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-01-285-1090

A047B0

Federal Item Identification Guide (FIIG_4065)

00209

Item Naming Code (INC_4080)

7 Sep 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5915-01-285-1090 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YQ011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5915-01-285-1090 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3249ZD1555  25120  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-01-285-1090 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59767 Sep 1988
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

7 Sep 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-01-285-1090 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
9Z
Code Definitions

9Z

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-K, Battle Creek, MI 49037-3084

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-01-285-1090 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.625 INCHES MAXIMUM
ADAQBody Length1.510 INCHES MAXIMUM
ADATBody Width0.707 INCHES MAXIMUM
CRBCDiscrimination At Specified Frequencies Per Function In Decibels3.0 MINIMUM BLANK AND 90.0 MAXIMUM BLANK
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length1.260 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width0.157 INCHES NOMINAL
CRBBFrequency Band Width Per Function7.50 KILOHERTZ BLANK AND 25.00 KILOHERTZ BLANK
CQDWFunctional Terminal Type And Quantity2 PIN INPUT-OUTPUT AND 4 PIN GROUND
AXHRMounting Facility Type And Quantity6 TERMINAL
AKNAInclosure TypeENCAPSULATED
CQDRInsertion Loss At Reference Frequency Per Function In Decibels3.5 BLANK
AHASLoad Impedance Per Function910.0 OHMS BLANK
AHBLPrincipal Circuitry Type Per FunctionCRYSTAL BLANK
AHAJReference Frequency Per Function10.7 MEGAHERTZ BLANK
AHAQSource Impedance Rating Per Function910.0 OHMS BLANK
ABKWOverall Height0.762 INCHES NOMINAL
CQFCSpecified Frequencies Of Discrimination Per Function7.500 KILOHERTZ BLANK AND 17.50 KILOHERTZ BLANK AND 25.00 KILOHERTZ BLANK
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Back to Top
Back to Top