Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
325411-2 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 37695 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 013181733 | A047B0 | 00209 | X | 1 | A | P | A | 0 | 13 Apr 1990 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YQ01 | 1 Jan 2015 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 6 | 13 Apr 1990 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | MFX 711-1 |
ADAU | Body Height | 0.320 INCHES NOMINAL |
ADAQ | Body Length | 1.160 INCHES NOMINAL |
ADAT | Body Width | 0.310 INCHES NOMINAL |
CBBL | Features Provided | MOISTURE RESISTANT |
CRBB | Frequency Band Width Per Function | 210.00 MEGAHERTZ BLANK AND 280.00 MEGAHERTZ BLANK |
CQDW | Functional Terminal Type And Quantity | 2 PRINTED CIRCUIT INPUT-OUTPUT AND 3 PRINTED CIRCUIT GROUND |
CRDC | Maximum Dielectric Withstanding Dc Voltage | 100.0 VOLTS AT SEA LEVEL |
AXHR | Mounting Facility Type And Quantity | 5 TERMINAL |
AFGA | Operating Temp Range | -55.0/+85.0 DEG CELSIUS |
AKNA | Inclosure Type | HERMETICALLY SEALED |
CQDR | Insertion Loss At Reference Frequency Per Function In Decibels | 8.0 BLANK |
AHAS | Load Impedance Per Function | 50.0 OHMS BLANK |
AHAJ | Reference Frequency Per Function | 230.0 MEGAHERTZ BLANK |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS BLANK |
ABKW | Overall Height | 0.460 INCHES NOMINAL |
FEAT | Special Features | IN/OUT TERMINALS ARE INSULATED PRINTED CIRCUIT PIN TYPE; GROUND TERMINALS ARE NON-INSULATED PRINTED CIRCUIT PIN TYPE |
AHBZ | Voltage Standing Wave Ratio Per Function | 1.5 BLANK |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |