5915-01-342-2772

FILTER,RADIO FREQUENCY INTERFERENCE


5915-01-342-2772 (5915013422772, 013422772)
Part Numbers (2 listings): 3452578-1 | 21-299415-35S |
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 18 Jul 1991

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-01-342-2772 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
3452578-13 - Design Control Reference2 - Production ItemSENSOR AND ANTENNA SYSTEMS,  93346    CAGE 93346  
21-299415-35S5 - Replaced / Discontinued2 - Production ItemAMPHENOL CORPORATION  77820    CAGE 77820  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5915-01-342-2772 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915013422772A047B000765X44APA18 Jul 1991
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

013422772

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-01-342-2772

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

18 Jul 1991

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

4

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5915-01-342-2772 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNN9ND1CZKEKE1 Jul 2005
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5915-01-342-2772 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ATX3452578-1  93346   CAGE/93346
525TX21-299415-35S  77820   CAGE/77820
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-01-342-2772 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX020 Jul 1991
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 Jul 1991

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-01-342-2772 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP061990X58500ELECTRICAL-EQUIP-FILTERS
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061990

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

58500

Uniform Freight Classification (UFC_CD_MODF_3040)

ELECTRICAL-EQUIP-FILTERS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5915-01-342-2772 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU0EA0
DSSMSJU0EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-01-342-2772 Submit RFQ
MRCDecoded RequirementClear Text Reply
CQRGBody MaterialALUMINUM
CRSTBody Surface TreatmentCADMIUM
CBBLFeatures ProvidedMOISTURE RESISTANT AND SHOCK RESISTANT
CQDWFunctional Terminal Type And Quantity37 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT
CRDCMaximum Dielectric Withstanding Dc Voltage500.0 VOLTS AT SEA LEVEL
AKEJMounting Facility Screw Thread Series DesignatorUNEF
AXHRMounting Facility Type And Quantity1 THREADED BUSHING
CQJXNominal Thread Size1.125 INCHES
AHBCOperating Current Rating Per Function In Amps5.0 1ST RADIO INTERFERENCE5.0 2ND RADIO INTERFERENCE5.0 3RD RADIO INTERFERENCE5.0 4TH RADIO INTERFERENCE5.0 5TH RADIO INTERFERENCE5.0 6TH RADIO INTERFERENCE
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQGCOperating Voltage Rating And Type Per Function200.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION200.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION200.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION200.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION200.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION200.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
AKNAInclosure TypeENCASED
AHASLoad Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE50.0 OHMS 2ND RADIO INTERFERENCE50.0 OHMS 3RD RADIO INTERFERENCE50.0 OHMS 4TH RADIO INTERFERENCE50.0 OHMS 5TH RADIO INTERFERENCE50.0 OHMS 6TH RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz400.0 1ST RADIO INTERFERENCE400.0 2ND RADIO INTERFERENCE400.0 3RD RADIO INTERFERENCE400.0 4TH RADIO INTERFERENCE400.0 5TH RADIO INTERFERENCE400.0 6TH RADIO INTERFERENCE
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE50.0 OHMS 2ND RADIO INTERFERENCE50.0 OHMS 3RD RADIO INTERFERENCE50.0 OHMS 4TH RADIO INTERFERENCE50.0 OHMS 5TH RADIO INTERFERENCE50.0 OHMS 6TH RADIO INTERFERENCE
AECRVibration Resistance Range In Hertz+10.0/+2000.0


Back to Top