5915-01-384-5511

FILTER,BAND PASS


5915-01-384-5511 (5915013845511, 013845511)
Part Numbers (3 listings): 10323-0010-01 | F-5106/UR | RF-591A-01 |
Summary

FSG 59 / FSC 5915

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 17 Dec 1993

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-01-384-5511 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
10323-0010-013 - Design Control Reference2 - Production ItemHARRIS CORPORATION  14304    CAGE 14304  
F-5106/UR5 - Replaced / Discontinued2 - Production ItemJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
RF-591A-015 - Replaced / Discontinued2 - Production ItemHARRIS CORPORATION  14304    CAGE 14304  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5915-01-384-5511 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915013845511A047B000209XM6BPAA017 Dec 1993
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

013845511

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-01-384-5511

A047B0

Federal Item Identification Guide (FIIG_4065)

00209

Item Naming Code (INC_4080)

17 Dec 1993

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5915-01-384-5511 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Oct 1996
ZW011 Nov 1998
WE011 Oct 2010
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5915-01-384-5511 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
323ZZ10323-0010-01  14304   CAGE/14304
523ZZRF-591A-01  14304   CAGE/14304
45269ZDF-5106/UR  80058   CAGE/80058
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-01-384-5511 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Dec 1993
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Dec 1993

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-01-384-5511 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TKM723Z9AHZG063035X35070
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

M

Less Than Carload (LCL_CD_2760)


85

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

G

Less Than Truckload (CLAS_RTNG_CD_2770)


125

063035

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35070

Uniform Freight Classification (UFC_CD_MODF_3040)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-01-384-5511 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item Identification5895-01-132-7204, COMMUNICATIONS SYSTEM, AN/GRC-212
FTLDFunctional DescriptionPROVIDES EXTRA RECEIVE SYSTEM SELECTIVITY REQUIRED WHEN OPERATING IN THE PRESENCE OF STRONG UNDESIRED RF SIGNALS
ABKWOverall Height3.500 INCHES NOMINAL
ABHPOverall Length20.000 INCHES NOMINAL
ABMKOverall Width19.000 INCHES NOMINAL
FEATSpecial FeaturesVOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC AND 230.0 AC; WATTAGE RATING 50 WATTS; MAY ALSO BE USED AS A POST SELECTOR (ON THE OUTPUT OF A TRANSMITTER); LOCAL OR REMOTE CONTROLLED BY A RECEIVER, RF INPUT DISABLES ABOVE 10VRMS, IMPEDANCE; 50 OHMS, OPERATING TEMPERATURE -10 TO +55 DEG CEL; STORAGE TEMPERATURE -62 TO +71 DEG CEL; FREQUENCY 10KHZ TO 30MHZ; 10MS SWITCHING SPEED; AUTOMATIC PRE/POST SELECTOR SWITCHING FOR TRANSCEIVER APPLICATIONS


Back to Top
Back to Top