5915-01-466-0893

FILTER,RADIO FREQUENCY INTERFERENCE


5915-01-466-0893 (5915014660893, 014660893)
Part Number (1 listing): A3T5AF
Summary

FSG 59 / FSC 5915

DEMIL: D

DEMIL INT: 1

HMIC: P

Date Created: 6 Jul 1999

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-01-466-0893 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
A3T5AF3 - Design Control Reference2 - Production ItemFILTER CONCEPTS INCORPORATED  64135      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5915-01-466-0893 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915014660893A047B000765X1DPAA06 Jul 1999
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

014660893

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-01-466-0893

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

6 Jul 1999

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5915-01-466-0893 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZK011 Jul 1999
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5915-01-466-0893 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDA3T5AF  64135  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-01-466-0893 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX08 Jul 1999
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Jul 1999

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-01-466-0893 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XF

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-01-466-0893 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length7.000 INCHES NOMINAL
ADATBody Width4.000 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length3.250 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width7.810 INCHES NOMINAL
AGAVEnd Item IdentificationSTAR WINDOW AIRBORNE SYSTEM AND RCT
AHCJFull Load Insertion Loss Frequencies In Megahertz0.02 AND 0.05 AND 0.15 AND 1.5 AND 5.0 AND 50.0
AHCKFull Load Minimum Insertion Loss At Specified Frequency In Decibels24.0 AND 34.0 AND 65.0 AND 65.0 AND 65.0 AND 60.0
CQDWFunctional Terminal Type And Quantity1 THREADED STUD GROUND 3RD FUNCTION
CQDWFunctional Terminal Type And Quantity3 THREADED STUD INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity3 THREADED STUD OUTPUT 2ND FUNCTION
AXHRMounting Facility Type And Quantity4 SLOT
ABTDMounting Slot Width0.180 INCHES NOMINAL
AHBCOperating Current Rating Per Function In Amps5.0 1ST RADIO INTERFERENCE
AHBCOperating Current Rating Per Function In Amps5.0 3RD RADIO INTERFERENCE
AHBCOperating Current Rating Per Function In Amps5.0 2ND RADIO INTERFERENCE
CQGCOperating Voltage Rating And Type Per Function125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOperating Voltage Rating And Type Per Function125.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOperating Voltage Rating And Type Per Function125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AKNAInclosure TypeENCASED
AHASLoad Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE
AHASLoad Impedance Per Function50.0 OHMS 3RD RADIO INTERFERENCE
AHASLoad Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz400.0 1ST RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz400.0 2ND RADIO INTERFERENCE
AHBBPower Line Frequency Rating Per Function In Hertz400.0 3RD RADIO INTERFERENCE
AHAQSource Impedance Rating Per Function50.0 CNB OHMS PER 1000 FEET
AHAQSource Impedance Rating Per Function50.0 CNB OHMS PER FOOT
AHAQSource Impedance Rating Per Function50.0 CNB OHMS PER MILE
ABKWOverall Height4.000 INCHES NOMINAL
ABHPOverall Length8.620 INCHES NOMINAL
FEATSpecial FeaturesLOW PASS EMI FILTER FOR ELIMINATING POWER LINE INTERFERENCE; 3 PHASE
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Back to Top
Back to Top