Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
FHN20G | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | |
MIL-PRF-19207/11 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
342004 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342003 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342005 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
2360-3105 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | BOC GROUP INC THE | 80382 | |
006-001371 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26916 | |
006000996 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26916 | |
335310 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 02769 | |
4134600-002 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | RAYTHEON COMPANY | 82577 | |
70031-4 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | RAYTHEON COMPANY | 82577 | |
186850-1 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | RAYTHEON COMPANY | 37695 | |
SC17900 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | PARISI ASSOCIATES, INC. | 27965 | |
SMD338876-3 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | |
SMB416802 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | |
1152001P2 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | BAE SYSTEMS INFORMATION AND | 94117 | |
5M.4851.220.04 | 5 - Replaced / Discontinued | 2 - Production Item | EADS DEUTSCHLAND GMBH | D1901 | |
29777-001 | 5 - Replaced / Discontinued | 2 - Production Item | ROCKWELL COLLINS DEUTSCHLAND GMBH | D9853 | |
335310 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 56232 | |
188157 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 37695 | |
W 4661 306 | 5 - Replaced / Discontinued | 9 - No Longer Used | OERLIKON-BUEHRLE AG | S3118 | |
BS-A76R1R | 5 - Replaced / Discontinued | 9 - No Longer Used | BRITISH SAROZAL LTD | K0577 | |
4806-3009-000 | 5 - Replaced / Discontinued | 9 - No Longer Used | DNE TECHNOLOGIES, INC. | 96238 | |
W 4661 306 | 5 - Replaced / Discontinued | 9 - No Longer Used | RHEINMETALL AIR DEFENCE AG | S3092 | |
FHN20G2 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | |
MIL-F-19207/11 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | |
FHN20G100H1 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
342004SA2 | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342003SA1 | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342022L | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342022 | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
20-174018 | C - Advisory Reference | 1 - Incomplete Part Number | ADAGE INC | 11359 | |
900961-00 | C - Advisory Reference | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 90536 | |
FHN206 | C - Advisory Reference | 1 - Incomplete Part Number | COOPER BUSSMANN INC | 71400 | |
HKPQW | C - Advisory Reference | 1 - Incomplete Part Number | COOPER BUSSMANN INC | 71400 | |
342004 | C - Advisory Reference | 1 - Incomplete Part Number | COOPER BUSSMANN INC | 71400 | |
342005 | C - Advisory Reference | 1 - Incomplete Part Number | COOPER BUSSMANN INC | 71400 | |
MILF19207-0011D | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
MILF19207-11C | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
GF816P1 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | |
1-00020 | C - Advisory Reference | 1 - Incomplete Part Number | TELEPHONE SYSTEMS/COMMUNICATIONS | 10241 | |
68151002001 | C - Advisory Reference | 1 - Incomplete Part Number | KOLLSMAN, INC. | 89944 | |
4134600-2 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 05869 | |
4134600-002 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 05869 | |
714299-5 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 05869 | |
343-1010P3 | C - Advisory Reference | 1 - Incomplete Part Number | L-3 COMMUNICATIONS KLEIN ASSOCIATES, | 52315 | |
60900212002 | C - Advisory Reference | 1 - Incomplete Part Number | DYNETCOM INC | 56657 | |
0686-3315 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | |
48063009-000 | C - Advisory Reference | 1 - Incomplete Part Number | DNE TECHNOLOGIES, INC. | 96238 | |
342003 | C - Advisory Reference | 1 - Incomplete Part Number | DATA ENTRY INC | 75919 | |
A-182W15 | C - Advisory Reference | 1 - Incomplete Part Number | UNION CARBIDE CORP | 36346 | |
324537 | C - Advisory Reference | 1 - Incomplete Part Number | AVTRON AEROSPACE, INC. | 01014 | |
16750232-001 | C - Advisory Reference | 1 - Incomplete Part Number | SYPRIS ELECTRONICS, LLC | 28009 | |
1100-1890 | C - Advisory Reference | 1 - Incomplete Part Number | E AND R ELECTRONICS INC | 30669 | |
123-003-0001 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 95542 | |
368-043 | C - Advisory Reference | 1 - Incomplete Part Number | TEST DEVICES INC | 58016 | |
135628-000 | C - Advisory Reference | 1 - Incomplete Part Number | BAE SYSTEMS INFORMATION AND | 81413 | |
201355-001 | C - Advisory Reference | 1 - Incomplete Part Number | BAE SYSTEMS INFORMATION AND | 81413 | |
566320 | C - Advisory Reference | 1 - Incomplete Part Number | HAMILTON SUNDSTRAND CORPORATION | 73030 | |
506471 | C - Advisory Reference | 1 - Incomplete Part Number | HAMILTON SUNDSTRAND CORPORATION | 73030 | |
SFL-2204-55 | C - Advisory Reference | 1 - Incomplete Part Number | BRENNER METAL PRODUCTS (INC) | 62728 | |
100028-005 | C - Advisory Reference | 1 - Incomplete Part Number | HITECH ENGINEERING CO INC THE | 9X735 | |
343-1010P3 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | |
8851065 | C - Advisory Reference | 1 - Incomplete Part Number | PICATINNY ARSENAL | 19203 | |
L2088148-1 | C - Advisory Reference | 1 - Incomplete Part Number | BENDIX CORP THE | 06840 | |
427C612H02 | C - Advisory Reference | 1 - Incomplete Part Number | WESTINGHOUSE ELECTRIC CORP | 88725 | |
55-198-998 | C - Advisory Reference | 1 - Incomplete Part Number | COMMUNICATIONS & POWER INDUSTRIES | 99313 | |
HRK00-005 | C - Advisory Reference | 1 - Incomplete Part Number | VEECO INSTRUMENTS INC | 80103 | |
5023-573 | C - Advisory Reference | 1 - Incomplete Part Number | VEECO INSTRUMENTS INC | 80103 | |
TXCBS0106 | C - Advisory Reference | 1 - Incomplete Part Number | COMTEC INFORMATION SYSTEMS INC | 04643 | |
309A4892 | C - Advisory Reference | 1 - Incomplete Part Number | MOTOROLA INC. | 94990 | |
342003SA2 | C - Advisory Reference | 1 - Incomplete Part Number | MOTOROLA INC. | 94990 | |
800137 | C - Advisory Reference | 1 - Incomplete Part Number | NAI TECHNOLOGIES INC | 07342 | |
FH5048 | C - Advisory Reference | 1 - Incomplete Part Number | HUGHEY & PHILLIPS INC | 94295 | |
265-1023-000 | C - Advisory Reference | 1 - Incomplete Part Number | ALCATEL USA INC. | 95104 | |
T-250-2066 | C - Advisory Reference | 1 - Incomplete Part Number | LUCENT TECHNOLOGIES INC | 06KW9 | |
5585734 PIECE 63 | C - Advisory Reference | 1 - Incomplete Part Number | NAVAL SEA SYSTEMS COMMAND | 53711 | |
109381 | C - Advisory Reference | 1 - Incomplete Part Number | TYMSHARE INC | 56200 | |
027594-0001 | C - Advisory Reference | 1 - Incomplete Part Number | THALES DEFENSE & SECURITY, INC. | 65597 | |
746121 | C - Advisory Reference | 1 - Incomplete Part Number | EXELIS INC. | 28527 | |
265-1023-000 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL COLLINS, INC. | 13499 | |
10088016-101 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 94580 | |
03004062 ITEM 22 | C - Advisory Reference | 1 - Incomplete Part Number | LEICA INC | 78039 | |
2360-3105 | C - Advisory Reference | 1 - Incomplete Part Number | AIRCO WELDING PRODUCTS | 94080 | |
ES7120008 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN-CANADA LTD | 95093 | |
32025A | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
32025A | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
340166 | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
340165 | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342-025A | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
342-025A | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
340117 | C - Advisory Reference | 1 - Incomplete Part Number | LITTELFUSE, INC. | 75915 | |
SM-B-386024 | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | |
SM-B-249225 | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | |
SM-B-249225 | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | |
328211303Z | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | |
7707288P4 | C - Advisory Reference | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 03538 | |
2500157 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 07187 | |
250-003 | C - Advisory Reference | 1 - Incomplete Part Number | JOHNSON E F CO | 13848 | |
34020 | E - Replace Reference Number | 8 - Replacement NSN | LITTELFUSE, INC. | 75915 | |
851804 | E - Replace Reference Number | 8 - Replacement NSN | SUPERIOR ELECTRIC HOLDING GROUP LLC | 58474 |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5920 | 005560144 | A014A0 | 28909 | X | 1 | A | P | S | 0 | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
B031 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G280 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G860 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G880 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G070 | 0 | 0 | L | 1 Apr 1991 | ||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YD01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZX01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YW01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YA01 | 1 Sep 2000 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
G26X | G26E | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
MC49 | MC13 | 1 | T | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 1 | T | Z | GH | GT | KE | JS | JB | HX | HS | HD | JV | 1 Aug 2006 | ||||||||||||||||
S911 | S007 | 1 | T | Z | XN | 1 Aug 2006 | ||||||||||||||||||||||||
BGX1 | BTX1 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
C911 | C007 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
FXGX | FXTX | 1 | T | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
A918 | A196 | 1 | T | Z | CD | AJ | CT | CL | 1 Aug 2006 | |||||||||||||||||||||
WP01 | 1 Oct 2006 | |||||||||||||||||||||||||||||
YQ01 | 1 Jan 2015 | |||||||||||||||||||||||||||||
YY01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
YK01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Naval ICP, Philadelphia, PA 19111
Naval ICP, Mechanicsburg, PA 17055-0788
Navy ICP, Mechanicsburg, PA 17055-0788
HD
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Strategic Systems Programs C/O Tracor Sys Engineering Rockville, MD 20850-1160
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | 3 | TX | D | FHN20G | 81349 | |||||
4 | 1 | E | ZZ | MIL-PRF-19207/11 | 81349 | |||||||
3 | 5 | 1 | 6 | TX | D | 342004 | 75915 | |||||
3 | 5 | 1 | 6 | TX | D | 342003 | 75915 | |||||
3 | 5 | 1 | 2 | TX | D | SMB416802 | 80063 | |||||
3 | 5 | 1 | 1 | TX | D | SMD338876-3 | 80063 | |||||
3 | 5 | 1 | 6 | TX | D | 342005 | 75915 | |||||
5 | 1 | 5 | TX | 335310 | 02769 | |||||||
4 | 5 | 1 | 5 | SB | D | 006-001371 | 26916 | |||||
3 | 5 | 1 | 5 | TX | D | 006000996 | 26916 | |||||
3 | 5 | 1 | 5 | TX | D | SC17900 | 27965 | |||||
5 | 1 | 6 | 9Z | D | 186850-1 | 37695 | ||||||
3 | 5 | 1 | 5 | TX | D | 1152001P2 | 94117 | |||||
3 | 5 | 1 | 5 | TX | D | 4134600-002 | 82577 | |||||
3 | 5 | 1 | 5 | TX | D | 70031-4 | 82577 | |||||
3 | 5 | 1 | 4 | TX | D | 2360-3105 | 80382 | |||||
4 | 5 | 2 | 3 | ZG | A | 5M.4851.220.04 | D1901 | |||||
3 | 5 | 2 | 1 | ZG | D | 29777-001 | D9853 | |||||
1 | 5 | 9 | 2 | ZK | B | BS-A76R1R | K0577 | |||||
5 | 9 | 1 | ZG | B | W 4661 306 | S3092 | ||||||
4 | 5 | 9 | 1 | ZG | B | W 4661 306 | S3118 | |||||
1 | 5 | 9 | E | TX | B | FHN20G2 | 81349 | |||||
5 | 9 | E | ZZ | B | MIL-F-19207/11 | 81349 | ||||||
3 | 5 | 9 | 5 | TU | B | 4806-3009-000 | 96238 | |||||
3 | 5 | 9 | 2 | ZF | B | 188157 | 37695 | |||||
3 | 5 | 9 | 5 | TX | B | 335310 | 56232 | |||||
C | 1 | 4 | 48 | AH | 60900212002 | 56657 | ||||||
C | 1 | 5 | TX | AF | 368-043 | 58016 | ||||||
C | 1 | 5 | TX | AF | 343-1010P3 | 49956 | ||||||
C | 1 | 6 | ZZ | AC | 343-1010P3 | 52315 | ||||||
C | 1 | 6 | ZZ | AC | 5585734 PIECE 63 | 53711 | ||||||
C | 1 | 6 | ZZ | AC | 109381 | 56200 | ||||||
C | 1 | 6 | ZZ | AC | 16750232-001 | 28009 | ||||||
C | 1 | 6 | ZZ | AC | 0686-3315 | 28480 | ||||||
C | 1 | 6 | ZZ | AC | 746121 | 28527 | ||||||
C | 1 | 6 | ZZ | AC | 1100-1890 | 30669 | ||||||
C | 1 | 6 | ZZ | AC | A-182W15 | 36346 | ||||||
C | 1 | 5 | TX | AF | 7707288P4 | 03538 | ||||||
C | 1 | 5 | TX | AF | TXCBS0106 | 04643 | ||||||
C | 1 | 5 | TX | AF | 4134600-002 | 05869 | ||||||
C | 1 | 5 | TX | AF | 4134600-2 | 05869 | ||||||
C | 1 | 5 | TX | AF | 714299-5 | 05869 | ||||||
3 | C | 1 | 5 | 48 | D | L2088148-1 | 06840 | |||||
C | 1 | 6 | ZZ | AC | T-250-2066 | 06KW9 | ||||||
C | 1 | 6 | ZZ | AC | 2500157 | 07187 | ||||||
C | 1 | 5 | TX | AF | 800137 | 07342 | ||||||
C | 1 | 5 | TX | AF | 1-00020 | 10241 | ||||||
C | 1 | 5 | TX | AF | 20-174018 | 11359 | ||||||
C | 1 | 6 | ZZ | AC | 265-1023-000 | 13499 | ||||||
3 | C | 1 | 9 | 48 | D | 250-003 | 13848 | |||||
C | 1 | 5 | TX | AF | 8851065 | 19203 | ||||||
C | 1 | A | KE | AC | GF816P1 | 26512 | ||||||
C | 1 | 5 | TX | AF | 342022 | 75915 | ||||||
C | 1 | 6 | ZZ | AC | 342022L | 75915 | ||||||
C | 1 | 6 | ZZ | AC | 342003 | 75919 | ||||||
C | 1 | 6 | ZZ | AC | 03004062 ITEM 22 | 78039 | ||||||
C | 1 | 5 | TX | AF | 328211303Z | 80063 | ||||||
C | 1 | 5 | TX | AO | SM-B-249225 | 80063 | ||||||
C | 1 | 5 | TX | AF | SM-B-386024 | 80063 | ||||||
C | 1 | 6 | ZZ | AC | SFL-2204-55 | 62728 | ||||||
1 | C | 1 | 5 | 48 | B | AH | 027594-0001 | 65597 | ||||
C | 1 | 5 | TX | AF | 342004 | 71400 | ||||||
C | 1 | 6 | ZZ | AC | 342005 | 71400 | ||||||
C | 1 | 5 | TX | AF | FHN206 | 71400 | ||||||
C | 1 | 5 | TX | AF | HKPQW | 71400 | ||||||
C | 1 | 6 | ZZ | AC | 506471 | 73030 | ||||||
C | 1 | 6 | ZZ | AC | 566320 | 73030 | ||||||
C | 1 | 5 | TX | A5 | 32025A | 75915 | ||||||
C | 1 | 5 | TX | AF | 340117 | 75915 | ||||||
C | 1 | 6 | ZZ | AC | 340165 | 75915 | ||||||
C | 1 | 6 | ZZ | AC | 340166 | 75915 | ||||||
C | 1 | 5 | TX | AF | 5023-573 | 80103 | ||||||
C | 1 | 5 | TX | AF | HRK00-005 | 80103 | ||||||
C | 1 | 5 | TX | AF | 342003SA1 | 75915 | ||||||
C | 1 | 6 | ZZ | AC | 324537 | 01014 | ||||||
C | 1 | 6 | TX | AW | 342-025A | 75915 | ||||||
C | 1 | 6 | ZZ | AC | 342004SA2 | 75915 | ||||||
C | 1 | 6 | ZZ | AC | FHN20G100H1 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | MILF19207-0011D | 81349 | ||||||
C | 1 | 6 | ZZ | AC | MILF19207-11C | 81349 | ||||||
C | 1 | 6 | ZZ | AC | 135628-000 | 81413 | ||||||
C | 1 | 5 | TX | AF | 201355-001 | 81413 | ||||||
C | 1 | 5 | TX | AF | 48063009-000 | 96238 | ||||||
C | 1 | 6 | ZZ | AC | 55-198-998 | 99313 | ||||||
C | 1 | 5 | TX | AF | 100028-005 | 9X735 | ||||||
C | 1 | 5 | TX | AF | 427C612H02 | 88725 | ||||||
C | 1 | 5 | TX | AF | 68151002001 | 89944 | ||||||
C | 1 | 5 | TX | AF | 900961-00 | 90536 | ||||||
C | 1 | 5 | TX | AF | 2360-3105 | 94080 | ||||||
3 | C | 1 | 9 | 48 | D | FH5048 | 94295 | |||||
C | 1 | 5 | TX | AF | 10088016-101 | 94580 | ||||||
C | 1 | 5 | TX | AF | 309A4892 | 94990 | ||||||
C | 1 | 6 | ZZ | AC | 342003SA2 | 94990 | ||||||
C | 1 | 6 | ZZ | AC | ES7120008 | 95093 | ||||||
C | 1 | 6 | ZZ | AC | 265-1023-000 | 95104 | ||||||
C | 1 | 5 | TX | AF | 123-003-0001 | 95542 | ||||||
3 | E | 8 | 5 | KE | D | 34020 | 75915 | |||||
3 | E | 8 | 1 | KE | D | 851804 | 58474 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
DLIS-K, Battle Creek, MI 49037-3084
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Germany
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
United Kingdom
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
France
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Federal Aviation Administration, Oklahoma City, OK 73125
Federal Aviation Administration
Defense Logistics Agency
Navy
The reference number is of the type for which an indication of document availability is not required.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Naval ICP, Philadelphia, PA 19111
Army / Defense Logistics Agency
Navy / Defense Logistics Agency
Air Force / Defense Logistics Agency
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TX | 0 | 3 | TX | 0 | 8 Oct 1965 | 5920000870206 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 5 Dec 1965 | 5920002582467 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 19 Sep 1965 | 5920002837178 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 0 | 8 Oct 1965 | 5920002961679 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 6 | 23 Apr 2012 | 5920003183121 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 8 Oct 1965 | 5920005047657 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 3 Feb 1968 | 5920005536392 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 17 May 1989 | 5920005810299 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 8 Oct 1965 | 5920006427551 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 29 Aug 1965 | 5920006860302 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 8 Oct 1965 | 5920008496564 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 0 | 17 May 1989 | 5920008616082 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 3 Aug 1969 | 5920009334052 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 24 Aug 1968 | 5920009509761 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 1 Feb 1991 | 5920010490021 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 1 Oct 1998 | 5920010822056 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 17 May 1989 | 5920011441500 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 6 Nov 1997 | 5920011582373 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 26 Aug 1997 | 5920011618119 | 1 Feb 1991 |
1 | TX | 0 | 3 | TX | 1 | 17 May 1989 | 5920011820612 | 1 Feb 1991 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH-BOXES-ELEC-ENCLOSURES |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | D | U | 1 | Z | EA | 0 | |
DF | SMS | D | U | 1 | N | EA | 0 | |
DM | SMS | D | U | 1 | Z | EA | 0 | |
DN | SMS | D | U | 1 | EA | 0 | ||
DS | SMS | D | U | 1 | N | EA | 0 | |
GP | SMS | D | U | 1 | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | 00 | 0 | A1 | D3 | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
No requirement
Not Applicable
Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGUK | Accommodated Ferrule Diameter | 0.250 INCHES NOMINAL |
AGUJ | Accommodated Fuse Length | 1.250 INCHES NOMINAL |
AAFZ | Body Material | PLASTIC, DIALLYL PHTHALATE, MIL-M-14, TYPE SDG |
AAQL | Body Style | BUSHING MOUNTED TYPE |
ABKH | Bushing Diameter | 0.500 INCHES NOMINAL |
AGVF | Bushing Hole Diameter | 0.500 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
AGUU | Bushing Thread Length | 0.420 INCHES MINIMUM AND 0.460 INCHES MAXIMUM |
AGUV | Cap Diameter | 0.680 INCHES MINIMUM AND 0.690 INCHES MAXIMUM |
AFRG | Contact Material | ANY ACCEPTABLE |
AFRH | Contact Surface Treatment | SILVER PLATED, QQ-S-365 |
CQJL | Current Carrying Rating In Amps | 20.0 |
CSNM | Fuse Terminal Type Accommodated | FERRULE |
ADZC | Environmental Protection | DRIPPROOF |
AGVH | Flatted Side Bushing Hole Length | 0.468 INCHES MINIMUM AND 0.478 INCHES MAXIMUM |
AEVB | Mounting Hole Style | BUSHING MOUNTING |
ABTJ | Mounting Hole Quantity | 1 |
AGUE | Fuse Accommodation Quantity | 1 |
AGUT | Length From Front Protrusion To Mounting Surface | 0.710 INCHES MINIMUM AND 0.750 INCHES MAXIMUM |
ABHP | Overall Length | 1.710 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
ABMK | Overall Width | 0.990 INCHES MINIMUM AND 1.030 INCHES MAXIMUM |
ELEC | Voltage In Volts | 250.0 |
TTQY | Terminal Type And Quantity | 2 TAB, SOLDER LUG |
ABDN | Terminal Surface Treatment | SOLDER DIP AND TIN PLATED |
TEST | Test Data Document | 81349-MIL-F-19207/11 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |