5920-01-633-6633

FUSE,CARTRIDGE


5920-01-633-6633 (5920016336633, 016336633)
Part Number (1 listing): 473007.YRT1L
Summary

FSG 59 / FSC 5920

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 28 Nov 2014

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5920-01-633-6633 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
473007.YRT1L3 - Design Control Reference2 - Production ItemLITTELFUSE, INC.  75915    CAGE 75915  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5920-01-633-6633 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595920016336633A0170000248X1APAA028 Nov 2014
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5920

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Fuses, Arrestors, Absorbers, and Protectors

016336633

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5920-01-633-6633

A01700

Federal Item Identification Guide (FIIG_4065)

00248

Item Naming Code (INC_4080)

28 Nov 2014

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5920-01-633-6633 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Nov 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5920-01-633-6633 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43239ZD473007.YRT1L  75915   CAGE/75915
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5920-01-633-6633 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

EA

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5920-01-633-6633 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAQLBody StylePIGTAIL TYPE
CQPBCircuit Over-Current Interruption Delay Time In Seconds60.0 200 PCT OF CURRENT RATING
AFXFCircuit Over-Current Interruption TypeTIME DELAY
AEBJContinuous Current Rating In Amps7.0
CBBLFeatures ProvidedNONRENEWABLE FUSIBLE ELEMENT
AFXEMaximum Voltage Rating In Volts125.0 DC
CXCYPart Name Assigned By Controlling AgencyFUSE,CARTRIDGE
AFXHInterruption Indicator MethodNO VISUAL INDICATION
CSQNShort-Circuit/Interrupt Current Rating In Amps50.0
ADAVOverall Diameter3.173 MILLIMETERS NOMINAL
ABHPOverall Length7.11 MILLIMETERS NOMINAL
AEBTTerminal Diameter0.64 MILLIMETERS NOMINAL
ABJTTerminal Length38.1 MILLIMETERS NOMINAL


Back to Top