Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7274-12-7 1/2 | 3 - Design Control Reference | 2 - Production Item | SENSATA TECHNOLOGIES, INC | 82647 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 000451720 | A030A0 | 00136 | X | 1 | A | P | U | 11 May 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | 7274-12-7 1/2 | 82647 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 13 Sep 1967 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG | P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Germany
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT POLE ONE |
ADAQ | Body Length | 0.562 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
ADAT | Body Width | 0.750 INCHES NOMINAL |
ABXD | Bushing Length | 0.250 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.703 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 7.5 AMPERES AC SINGLE LOCATION AND 7.5 AMPERES AC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC SINGLE LOCATION AND 2000.0 DC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
AJWX | Mounting Surface To Terminal End Distance | 1.707 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.469 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | CORROSION RESISTANT AND EXPLOSION RESISTANT |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
AKPX | Pole Quantity | 1 |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
CMLP | Thread Quantity Per Inch | 32 |
THSD | Thread Series Designator | UNS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |