5925-00-089-4435

CIRCUIT BREAKER


5925-00-089-4435 (5925000894435, 000894435)
Part Number (1 listing): A1B320
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 13 Jun 1967

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-00-089-4435 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
A1B3203 - Design Control Reference9 - No Longer UsedSCHNEIDER ELECTRIC USA, INC.  63637    CAGE 63637  
A1B3205 - Replaced / Discontinued9 - No Longer UsedSCHNEIDER ELECTRIC USA, INC.  14280      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-00-089-4435 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925000894435A030A000136X1APA13 Jun 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

000894435

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-00-089-4435

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

13 Jun 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5925-00-089-4435 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
FXGX3HZSX1 Apr 2006
N9BN3HZHDGTHD1 Apr 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5925-00-089-4435 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
396CLA1B320  63637   CAGE/63637
359ECLBA1B320  14280  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG G - FREIGHT DATA | NSN 5925-00-089-4435 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CL658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

CL

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-00-089-4435 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSJU1NEA0
DNSMSJU1EA0
DSSMSJU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-00-089-4435 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPXPole Quantity3
CPLMMaximum Continuous Load Current Rating Per Pole20.0 AMPERES AC ALL LOCATIONS
CPRFOperating Voltage Type And Rating Per Pole In Volts240.0 AC ALL LOCATIONS
FREQFrequency In Hertz60.0 ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps7500.0 AC ALL LOCATIONS
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
CPRJTrip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
CRCFTrip Release Ambient Temp Rating40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
CPRLTrip Release CharacteristicTIME DELAY ALL LOCATIONS
CQWNTrip Delay Time In Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent135.0 ALL LOCATIONS
CPRQReset MethodMANUAL
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
AAQLBody StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBody Length3.000 INCHES NOMINAL
ADATBody Width2.230 INCHES MINIMUM
AEBPCenter To Center Distance Between Terminals Parallel To Length2.050 INCHES NOMINAL
AEBQCenter To Center Distance Between Terminals Parallel To Width0.750 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.250 INCHES NOMINAL
AJWXMounting Surface To Terminal End Distance3.150 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AXHRMounting Facility Type And Quantity6 TERMINAL
CPRTManual Actuator Type And Quantity1 PUSH-PULL
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE TWO
TTQYTerminal Type And Quantity6 COMPRESSION
CQXFInclosure Protection Type For Which DesignedGENERAL PURPOSE
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
AFJNFragility FactorMODERATELY RUGGED