Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
F3015 | 3 - Design Control Reference | 2 - Production Item | WESTINGHOUSE ELECTRIC CORP | 79500 | |
1222032 | 3 - Design Control Reference | 2 - Production Item | WESTINGHOUSE ELECTRIC CORP | 79500 | |
1222032 | 3 - Design Control Reference | 2 - Production Item | WESTINGHOUSE ELECTRIC CORP | 11660 | |
45-70 | 5 - Replaced / Discontinued | 2 - Production Item | EATON CORP | 15605 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 001740387 | A030A0 | 00136 | X | 1 | A | P | A | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Dec 1999 | |||||||||||||||||||||||||||||
ZU01 | 1 Mar 2008 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | A | TX | D | 1222032 | 11660 | |||||
3 | 3 | 2 | A | TX | D | 1222032 | 79500 | |||||
3 | 3 | 2 | E | TX | D | F3015 | 79500 | |||||
3 | 5 | 2 | 5 | TX | D | 45-70 | 15605 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 1 | 1 | TX | 0 | 14 Feb 1982 | 5925004225148 | 12 Feb 1982 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Defense Logistics Agency
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 42 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | FA | JC | X | EC | DO | Q | Q | O |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
MIL-P-130, laminated and creped wrapping paper
ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT POLE TWO |
APNQ | Arc Quenching Method | DEION |
ADAU | Body Height | 3.807 INCHES MINIMUM AND 3.817 INCHES MAXIMUM |
ADAQ | Body Length | 9.370 INCHES MINIMUM AND 9.380 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAT | Body Width | 4.120 INCHES MINIMUM AND 4.130 INCHES MAXIMUM |
AJEC | Boss Height | 0.120 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 7.245 INCHES MINIMUM AND 7.255 INCHES MAXIMUM |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.369 INCHES MINIMUM AND 1.379 INCHES MAXIMUM |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 4.495 INCHES MINIMUM AND 4.505 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.369 INCHES MINIMUM AND 1.379 INCHES MAXIMUM |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 15000.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AKPX | Pole Quantity | 3 |
CPRQ | Reset Method | MANUAL |
BBRJ | Special Handling Feature | MAGNETIC |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.276 INCHES MINIMUM AND 0.286 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |