5925-00-174-3319

CIRCUIT BREAKER


5925-00-174-3319 (5925001743319, 001743319)
Part Number (1 listing): AM12-30-250-60-4
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Replacement NSN:

5925-00-049-2072

Replacement Date: 1 Feb 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-00-174-3319 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AM12-30-250-60-43 - Design Control Reference9 - No Longer UsedEATON CORP  74193    CAGE 74193  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-00-174-3319 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925001743319A030A000136X1APA1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

001743319

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-00-174-3319

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5925-00-174-3319 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZG011 Apr 1991
ZR011 Jul 1997
ZW011 Nov 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-00-174-3319 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
339ETXDAM12-30-250-60-4  74193   CAGE/74193
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-00-174-3319 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
ETX1BTX01 Feb 1975 5925000492072 17 Mar 1971
Code Definitions

E

Item Standardization Code (ISC_2650)


An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5925-00-049-2072

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

17 Mar 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-00-174-3319 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
72DZ9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-00-174-3319 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-00-174-3319 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE ONE
APNQArc Quenching MethodMAGNETIC BLOWOUT
ADAQBody Length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
AAQLBody StyleSINGLE POLE TYPE
ADATBody Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AJECBoss Height0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length1.924 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AFJNFragility FactorMODERATELY RUGGED
FREQFrequency In Hertz60.0 SINGLE LOCATION
CPLMMaximum Continuous Load Current Rating Per Pole30.0 AMPERES AC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 AC SINGLE LOCATION
AXHRMounting Facility Type And Quantity2 THREADED HOLE
AJWXMounting Surface To Terminal End Distance2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
CQJXNominal Thread Size0.138 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts250.0 AC SINGLE LOCATION
CQXFInclosure Protection Type For Which DesignedFUNGUS RESISTANT
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 TOGGLE
AKPXPole Quantity1
CPRQReset MethodMANUAL
CQWNTrip Delay Time In Seconds Per Rated Continuous Current4.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CPRJTrip Release MethodMAGNETIC-HYDRAULIC SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 SINGLE LOCATION
PKWTUnpackaged Unit Weight4.250 OUNCES
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity2 THREADED STUD
CMLPThread Quantity Per Inch32
THSDThread Series DesignatorUNC


Back to Top