5925-00-229-3519

CIRCUIT BREAKER


5925-00-229-3519 (5925002293519, 002293519)
Part Number (1 listing): 150-0865
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 10 Feb 1969

Unit Weight: 325.0 lbs

Unit Size: 36in x 36in x 36in

Unit Pack Cube: 27.000 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-00-229-3519 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
150-08653 - Design Control Reference2 - Production ItemCONTINENTAL ELECTRONICS CORPORATION  52151    CAGE 52151  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-00-229-3519 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925002293519A030A000136X1APA010 Feb 1969
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

002293519

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-00-229-3519

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

10 Feb 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5925-00-229-3519 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N2H43RPEHDCNGG1 Apr 1991
YB011 Apr 1991
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

R

Acquisition Method Suffix Code (AMSC_2876)


The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

P

Nonconsumable Item Material Support Code (NIMSC_0076)


Total depot maintenance is being accomplished by commercial contract.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

CNDSOR

Depot Source of Repair Codes (DSOR_0903)


Contract, Contiguous United States (CONUS)

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 5925-00-229-3519 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1321HDD150-0865  52151   CAGE/52151
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-00-229-3519 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX021 Dec 1969
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Dec 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-00-229-3519 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
HHFFP658Z5AHYP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

HH

Originating Activity Code (ORIG_ACTY_CD_4210)


Navy ICP, Mechanicsburg, PA 17055-0788

FF

Hazardous Materiel Code (HMC_2720)


Code FF denotes special factors or conditions in an item description which have an effect on the ratings or charges; therefore, the item description should be read carefully to ensure that such special factors or conditions can be included as a part of the bill of lading description.

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

5

Special Handling Code (SP_HDLG_CD_9240)


Protected (Pilferable)

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Y

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-00-229-3519 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNNRPCU0HEA0
DNNRPJU1HEA0
Code Definitions

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

1

Quantity Unit Pack (QUP_6106)


1

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5925-00-229-3519 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APB531000325.0 lbs36in x 36in x 36in27.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00JALK0F200B03QFM
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

B

Item Type Storage Code (ITM_TYP_STOR_5156)


Unheated General Purpose

53

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Floating watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

325.0 lbs

Unit Pack Weight (UP_WT_5153)

36in x 36in x 36in

Unit Pack Size (UP_SZ_5154)

27.000 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

JA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-3174, plastic sheet, polyolefin, 2 mil

LK

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Wood blocking and bracing, fasteners, or steel strapping, for tie-down purposes. Rubber tired wheels shall be blocked clear of the floor of the crate or skid and shall not be load bearing.

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

F2

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D6251, Type III, Class 2, overseas cleated plywood box or ASTM-D6880, Class 2, heavy duty nailed wood box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

03

Special Marking Code (SP_MKG_CD_5169)


Mehod 50

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

F

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-00-229-3519 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionRESET
CPSFAdjustable Trip Setting Current Range Per Pole In Amps+280.0/+460.0 AC ALL LOCATIONS AND +1750.0/+5250.0 AC ALL LOCATIONS
CPRXActuator Position DesignationAT POLE ONE
CPRZAuxiliary Switch Function And Quantity12 ALARM
ADAUBody Height17.000 INCHES NOMINAL
ADAQBody Length17.562 INCHES NOMINAL
AAQLBody StyleRECTANGULAR DIMENSIONAL ENVELOPE
ADATBody Width12.750 INCHES NOMINAL
ADTVCase MaterialMETAL
AEBPCenter To Center Distance Between Terminals Parallel To Length3.625 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length11.625 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width10.562 INCHES NOMINAL
CPRYExternal Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
CBBLFeatures ProvidedADJUSTABLE TRIP RELEASE
FREQFrequency In Hertz60.0 ALL LOCATIONS
CPLMMaximum Continuous Load Current Rating Per Pole600.0 AMPERES AC ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps35000.0 AC ALL LOCATIONS
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
ABTDMounting Slot Width0.187 INCHES NOMINAL
CPRFOperating Voltage Type And Rating Per Pole In Volts600.0 AC ALL LOCATIONS
CPSMInternal Trip Release ConfigurationSHUNT TRIP ALL LOCATIONS
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 ROTARY
AKPXPole Quantity3
CQTLReset Actuator Voltage Rating And Type In Volts208.0 AC
CPRQReset MethodELECTRIC
ABKWOverall Height16.188 INCHES NOMINAL
ABHPOverall Length17.000 INCHES NOMINAL
ABMKOverall Width12.750 INCHES NOMINAL
FEATSpecial FeaturesLONG DELAY PICKUP,LONG TIME DELAYBAND,INSTANTANEOUS PICKUP SETTINGS ADJUSTABLE.
CQWNTrip Delay Time In Seconds Per Rated Continuous Current75.000 MINIMUM AT 100 PCT ALL LOCATIONS AND 1000.000 MAXIMUM AT 100 PCT ALL LOCATIONS AND 46.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 300.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 40.000 MINIMUM AT 300 PCT ALL LOCATIONS AND 150.000 MAXIMUM AT 300 PCT ALL LOCATIONS AND 34.000 MINIMUM AT 400 PCT ALL LOCATIONS AND 90.000 MAXIMUM AT 400 PCT ALL LOCATIONS AND 28.000 MINIMUM AT 500 PCT ALL LOCATIONS AND 65.000 MAXIMUM AT 500 PCT ALL LOCATIONS AND 10.000 MINIMUM AT 1000 PCT ALL LOCATIONS AND 18.000 MAXIMUM AT 1000 PCT ALL LOCATIONS
CPRLTrip Release CharacteristicINSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS
CPRJTrip Release MethodMAGNETIC ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 ALL LOCATIONS
CPRPUltimate Trip Time Per Pole In Seconds56.000 NOMINAL ALL LOCATIONS
AEBVUnthreaded Mounting Hole Diameter0.500 INCHES NOMINAL
AEGJSwitch Contact ArrangementSINGLE POLE, DOUBLE THROW
CSSXSwitch Current Rating And Type In Amps12.0 AC AND 24.0 DC
CRTKSwitch Terminal TypeTHREADED STUD
CSWPSwitch Voltage Rating And Type In Volts208.0 AC AND 46.0 DC
TTQYTerminal Type And Quantity6 BUS BAR


Back to Top
Back to Top