Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
49B6768-25 | 3 - Design Control Reference | 2 - Production Item | DEPARTMENT OF THE AIR FORCE | 80049 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 003995982 | A030A0 | 00136 | X | M | 9 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 11 Mar 1980 | 5925010793085 | 3 Oct 1971 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES AC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1200.0 AC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | THD BUSHING |
CQJX | Nominal Thread Size | 0.138 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 115.0 AC SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
AKPX | Pole Quantity | 1 |
CPRQ | Reset Method | MANUAL |
ABKW | Overall Height | 2.688 INCHES NOMINAL |
ABHP | Overall Length | 2.188 INCHES NOMINAL |
ABMK | Overall Width | 0.750 INCHES NOMINAL |
FEAT | Special Features | RED BAND VISIBLE IN TRIP POSITION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 100.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 10.000 NOMINAL AT 400 PCT SINGLE LOCATION AND 3600.000 NOMINAL AT 138 PCT SINGLE LOCATION |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 SCREW |
CMLP | Thread Quantity Per Inch | 32 |
THSD | Thread Series Designator | UNC |