5925-00-833-7952

CIRCUIT BREAKER


5925-00-833-7952 (5925008337952, 008337952)
Part Number (1 listing): TF126015
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1962

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-00-833-7952 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TF1260153 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  60969    CAGE 60969  
TF1260155 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-00-833-7952 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925008337952A030A000136XM9APS1 Jan 1962
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

008337952

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-00-833-7952

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5925-00-833-7952 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G86000C1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-00-833-7952 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX010 May 1971
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 May 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-00-833-7952 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-00-833-7952 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNQArc Quenching MethodDEION
ADAUBody Height4.313 INCHES NOMINAL
ADAQBody Length9.375 INCHES NOMINAL
AAQLBody StyleSINGLE POLE TYPE
ADATBody Width2.750 INCHES NOMINAL
ADTVCase MaterialPLASTIC
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
CPLMMaximum Continuous Load Current Rating Per Pole15.0 AMPERES AC ALL LOCATIONS AND 15.0 AMPERES DC ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps15000.0 AC ALL LOCATIONS AND 15000.0 DC ALL LOCATIONS
AXHRMounting Facility Type And Quantity4 THREADED HOLE
CPRFOperating Voltage Type And Rating Per Pole In Volts600.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS
CPRTManual Actuator Type And Quantity1 TOGGLE
AKPXPole Quantity2
PRMTPrecious MaterialSILVER
CPRQReset MethodMANUAL
CRCFTrip Release Ambient Temp Rating25.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
CPRLTrip Release CharacteristicINSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS
CQQCTrip Release Duty CycleCONTINUOUS ALL LOCATIONS
CPRJTrip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
CQWNTrip Delay Time In Seconds Per Rated Continuous Current200.000 NOMINAL AT 125 PCT ALL LOCATIONS AND 18.000 NOMINAL AT 200 PCT ALL LOCATIONS AND 0.700 NOMINAL AT 300 PCT ALL LOCATIONS
TTQYTerminal Type And Quantity4 SCREW


Back to Top