Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
711570-251 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 05869 | ![]() |
711570-251 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON COMPANY | 82577 | ![]() |
70-132-38MG6 | 5 - Replaced / Discontinued | 9 - No Longer Used | EATON CORP | 74193 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 008533828 | A030A0 | 00136 | X | 1 | A | P | A | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB | ||||||||||||||||||||||||||||||
ZR | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
N9BN | 3 | H | Z | GH | HD | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | A | TX | 711570-251 | 05869 | ![]() | ||||||
3 | 5 | 2 | A | TX | D | 711570-251 | 82577 | ![]() | ||||
3 | 5 | 9 | E | TX | B | 70-132-38MG6 | 74193 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH-BOXES-ELEC-ENCLOSURES |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT POLE ONE |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADAQ | Body Length | 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM |
AAQL | Body Style | SINGLE POLE TYPE |
ADAT | Body Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
AJEC | Boss Height | 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.75 AMPERES AC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 2.775 INCHES MINIMUM AND 2.955 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AKPX | Pole Quantity | 1 |
CPRQ | Reset Method | MANUAL |
BBRJ | Special Handling Feature | MAGNETIC |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
PKWT | Unpackaged Unit Weight | 0.312 POUNDS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CSSX | Switch Current Rating And Type In Amps | 5.0 AC AND 1.0 DC |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CSWP | Switch Voltage Rating And Type In Volts | 115.0 AC AND 50.0 DC |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
TEST | Test Data Document | 05869-711570 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
THSD | Thread Series Designator | UNC |
CMLP | Thread Quantity Per Inch | 32 |