5925-00-877-6757

CIRCUIT BREAKER


5925-00-877-6757 (5925008776757, 008776757)
Part Number (1 listing): 102-205-101
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 18 Aug 1967

Replacement NSN:

5925-00-344-1910

Replacement Date: 25 Jan 1974

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-00-877-6757 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
102-205-1013 - Design Control Reference9 - No Longer UsedWOOD ELECTRIC OPERATIONS POTTER AND  79405      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-00-877-6757 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925008776757XAPU18 Aug 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

008776757

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-00-877-6757

18 Aug 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Type of Item Identification (TYP_II_4820)


NSN Center Does Not Have An Explanation

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5925-00-877-6757 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YJ011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-00-877-6757 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3396CLD102-205-101  79405  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-00-877-6757 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
ETX1BTX025 Jan 1974 5925003441910 18 Jun 1973
Code Definitions

E

Item Standardization Code (ISC_2650)


An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

25 Jan 1974

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5925-00-344-1910

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

18 Jun 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-00-877-6757 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
96
Code Definitions

96

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-LFF, Battle Creek, MI 49037-3084

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-00-877-6757 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPXPole Quantity1
CPLMMaximum Continuous Load Current Rating Per Pole5.0 AMPERES AC AND
CPLMMaximum Continuous Load Current Rating Per Pole5.0 AMPERES DC SINGLE LOCATION
CPRFOperating Voltage Type And Rating Per Pole In Volts250.0 AC AND
CPRFOperating Voltage Type And Rating Per Pole In Volts32.0 DC SINGLE LOCATION
FREQFrequency In Hertz400.0 SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps3000.0 AC AND
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps3000.0 DC SINGLE LOCATION
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
CPRJTrip Release MethodTHERMAL SINGLE LOCATION
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CRCFTrip Release Ambient Temp Rating25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CQWNTrip Delay Time In Seconds Per Rated Continuous Current18.000 MINIMUM AT 200 PCT AND
CQWNTrip Delay Time In Seconds Per Rated Continuous Current70.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 SINGLE LOCATION
CPRQReset MethodMANUAL
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
AAQLBody StyleSINGLE POLE TYPE
ABXDBushing Length0.156 INCHES NOMINAL
ADAQBody Length2.189 INCHES NOMINAL
ADATBody Width0.750 INCHES NOMINAL
AEBPCenter To Center Distance Between Terminals Parallel To Length1.188 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length1.812 INCHES NOMINAL
AJWXMounting Surface To Terminal End Distance2.000 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AXHRMounting Facility Type And Quantity2 THREADED HOLE
THSDThread Series DesignatorUNC
CQJXNominal Thread Size0.138 INCHES
CMLPThread Quantity Per Inch32
CPRTManual Actuator Type And Quantity1 PUSH-PULL
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE ONE
TTQYTerminal Type And Quantity2 SCREW
CQXFInclosure Protection Type For Which DesignedSALT SPRAY PROOF AND
CQXFInclosure Protection Type For Which DesignedVIBRATIONPROOF
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE


Back to Top