Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
930-012-35 | 3 - Design Control Reference | 2 - Production Item | EATON CORPORATION | 76374 | ![]() |
930-012-35 | 3 - Design Control Reference | 2 - Production Item | EATON CORPORATION | 81640 | ![]() |
MP937B | 5 - Replaced / Discontinued | 2 - Production Item | EATON CORPORATION | 76374 | ![]() |
MP937B | 5 - Replaced / Discontinued | 2 - Production Item | EATON CORPORATION | 81640 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 008799456 | A030A0 | 00136 | X | 1 | A | P | U | 8 Nov 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR | ||||||||||||||||||||||||||||||
ZU | ||||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Aug 1995 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | A | TX | D | 930-012-35 | 76374 | ![]() | ||||
3 | 2 | A | ZZ | 930-012-35 | 81640 | ![]() | ||||||
3 | 5 | 2 | 6 | TX | D | MP937B | 76374 | ![]() | ||||
5 | 2 | 6 | ZZ | MP937B | 81640 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | P | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT EACH POLE |
ADAQ | Body Length | 2.188 INCHES MINIMUM AND 2.218 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAT | Body Width | 1.203 INCHES MINIMUM AND 1.233 INCHES MAXIMUM |
ABXD | Bushing Length | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
ADTV | Case Material | METAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.689 INCHES MINIMUM AND 0.719 INCHES MAXIMUM |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1200.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 3 THREADED BUSHING |
AJWX | Mounting Surface To Terminal End Distance | 1.860 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.469 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 3 PUSH-PULL |
AKPX | Pole Quantity | 3 |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 55.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 150.0 GRAMS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 6 TAB W/SCREW |
THSD | Thread Series Designator | UNS |
CMLP | Thread Quantity Per Inch | 32 |