5925-00-944-3848

CIRCUIT BREAKER


5925-00-944-3848 (5925009443848, 009443848)
Part Number (1 listing): AM12HK10-32VDC5
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Mar 1966

Replacement NSN:

5925-00-224-6070

Replacement Date: 31 Mar 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-00-944-3848 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AM12HK10-32VDC53 - Design Control Reference9 - No Longer UsedEATON CORP  74193    CAGE 74193  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-00-944-3848 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925009443848A030A000136X1APU1 Mar 1966
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

009443848

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-00-944-3848

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

1 Mar 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5925-00-944-3848 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Apr 1991
ZG011 Nov 2011
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-00-944-3848 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
339ETXDAM12HK10-32VDC5  74193   CAGE/74193
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-00-944-3848 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
ETX1BTX031 Mar 1975 5925002246070 3 Jan 1970
Code Definitions

E

Item Standardization Code (ISC_2650)


An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

31 Mar 1975

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5925-00-224-6070

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3 Jan 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-00-944-3848 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZG
Code Definitions

ZG

Originating Activity Code (ORIG_ACTY_CD_4210)


Germany

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-00-944-3848 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EJU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-00-944-3848 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE ONE
APNQArc Quenching MethodMAGNETIC BLOWOUT
CPRZAuxiliary Switch Function And Quantity1 ALARM
ADAQBody Length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
AAQLBody StyleSINGLE POLE TYPE
ADATBody Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AJECBoss Height0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AFJNFragility FactorMODERATELY RUGGED
CPLMMaximum Continuous Load Current Rating Per Pole10.0 AMPERES DC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps3000.0 DC SINGLE LOCATION
AXHRMounting Facility Type And Quantity2 THREADED HOLE
AJWXMounting Surface To Terminal End Distance2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
CQJXNominal Thread Size0.138 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts32.0 DC SINGLE LOCATION
CQXFInclosure Protection Type For Which DesignedGENERAL PURPOSE
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 TOGGLE
AKPXPole Quantity1
CPRQReset MethodMANUAL
CQWNTrip Delay Time In Seconds Per Rated Continuous Current0.150 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.550 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CPRJTrip Release MethodMAGNETIC-HYDRAULIC SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 SINGLE LOCATION
PKWTUnpackaged Unit Weight4.250 OUNCES
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
AEGJSwitch Contact ArrangementSINGLE POLE, DOUBLE THROW
CSSXSwitch Current Rating And Type In Amps2.5 AC AND 1.0 DC
CQSMSwitch Location And Position DesignationINTERNAL AT POLE ONE
CRTKSwitch Terminal TypeTAB, SOLDER LUG
CSWPSwitch Voltage Rating And Type In Volts250.0 AC AND 50.0 DC
TTQYTerminal Type And Quantity2 THREADED STUD
THSDThread Series DesignatorUNC
CMLPThread Quantity Per Inch32


Back to Top
Back to Top