Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
TJK636600ASA6AB3RS | 3 - Design Control Reference | 2 - Production Item | GENERAL ELECTRIC CO | 60969 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 010184862 | A030A0 | 00136 | X | 1 | A | P | U | 29 Mar 1976 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G900 | 0 | 0 | L | 1 Apr 1991 |
Not Established
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | 75 | TJK636600ASA6AB3RS | 60969 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
GSA, FSS/FCSC Washington, DC 20406
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 29 Mar 1976 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
90 |
Tennessee Valley Authority, Chattanooga, TN 37402-2801
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPSF | Adjustable Trip Setting Current Range Per Pole In Amps | +1800.0/+6000.0 AC SINGLE LOCATION |
CPRX | Actuator Position Designation | AT POLE TWO |
APNQ | Arc Quenching Method | AIR |
CPRZ | Auxiliary Switch Function And Quantity | 1 CONTROL |
ADAU | Body Height | 3.812 INCHES NOMINAL |
ADAQ | Body Length | 10.125 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAT | Body Width | 8.250 INCHES NOMINAL |
AJEC | Boss Height | 1.688 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 2.750 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 7.750 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 7.750 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.375 INCHES NOMINAL |
CBBL | Features Provided | ADJUSTABLE TRIP RELEASE |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CBME | Cubic Measure | 299.122 CUBIC INCHES |
CPLM | Maximum Continuous Load Current Rating Per Pole | 600.0 AMPERES AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 22000.0 AC ALL LOCATIONS AND 10000.0 DC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AKPX | Pole Quantity | 3 |
CPRQ | Reset Method | MANUAL |
FEAT | Special Features | SWITCH-RIGTT POLE MTD,LEADS OUT SIDE,3 ELEMENTS |
CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.190 INCHES NOMINAL |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CSSX | Switch Current Rating And Type In Amps | 6.0 AC AND 0.5 DC |
CQSM | Switch Location And Position Designation | EXTERNAL AT EACH POLE |
CRTK | Switch Terminal Type | WIRE LEAD |
CSWP | Switch Voltage Rating And Type In Volts | 600.0 AC AND 125.0 DC |
TTQY | Terminal Type And Quantity | 6 SCREW |