5925-01-039-3071

CIRCUIT BREAKER


5925-01-039-3071 (5925010393071, 010393071)
Part Number (1 listing): TJK636Y600
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 17 Apr 1977

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-039-3071 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TJK636Y6003 - Design Control Reference2 - Production ItemKRDC INC  60696      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-039-3071 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925010393071A030A000136X1APU17 Apr 1977
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

010393071

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-039-3071

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

17 Apr 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-039-3071 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-039-3071 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32E75TJK636Y600  60696  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-039-3071 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Apr 1977
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Apr 1977

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-039-3071 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
90
Code Definitions

90

Originating Activity Code (ORIG_ACTY_CD_4210)


Tennessee Valley Authority, Chattanooga, TN 37402-2801

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-039-3071 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPXPole Quantity3
CPLMMaximum Continuous Load Current Rating Per Pole600.0 AMPERES AC ALL LOCATIONS
CPRFOperating Voltage Type And Rating Per Pole In Volts600.0 AC ALL LOCATIONS
FREQFrequency In Hertz60.0 ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps25000.0 AC ALL LOCATIONS
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
CPRJTrip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
CRCFTrip Release Ambient Temp Rating35.0 DEG CELSIUS NOMINAL ALL LOCATIONS
CPRLTrip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 ALL LOCATIONS
CPRQReset MethodMANUAL
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
AAQLBody StyleMULTIPOLE-SINGLE ACTUATOR TYPE
ADAQBody Length10.125 INCHES NOMINAL
ADATBody Width8.125 INCHES NOMINAL
ADAUBody Height3.812 INCHES NOMINAL
AEBPCenter To Center Distance Between Terminals Parallel To Length7.749 INCHES NOMINAL
AEBQCenter To Center Distance Between Terminals Parallel To Width2.750 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length7.749 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width1.375 INCHES NOMINAL
AJECBoss Height1.688 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
AEBVUnthreaded Mounting Hole Diameter0.190 INCHES NOMINAL
CPRTManual Actuator Type And Quantity1 TOGGLE
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE ONE
TTQYTerminal Type And Quantity6 SCREW
APNQArc Quenching MethodAIR
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
AFJNFragility FactorMODERATELY RUGGED


Back to Top