Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2V2380 | 3 - Design Control Reference | 2 - Production Item | CATERPILLAR INC. | 11083 | ![]() |
CDLA-60 | 5 - Replaced / Discontinued | 2 - Production Item | SENSATA TECHNOLOGIES, INC | 82647 | ![]() |
CDLA60 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 96214 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 010699459 | A030A0 | 00136 | X | 1 | A | P | A | 29 Dec 1978 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZP | ||||||||||||||||||||||||||||||
ZR | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
ZP01 | 1 Feb 1997 | |||||||||||||||||||||||||||||
A918 | 3 | L | Z | CD | AZ | 1 Jun 2006 | ||||||||||||||||||||||||
FXGX | 3 | L | Z | SX | 1 Jun 2006 | |||||||||||||||||||||||||
MC49 | 3 | L | Z | PA | 1 Jun 2006 | |||||||||||||||||||||||||
N9BN | 3 | L | Z | HD | 1 Jun 2006 | |||||||||||||||||||||||||
ZR01 | 1 Dec 2007 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | TX | 2V2380 | 11083 | ![]() | ||||||
5 | 2 | E | TX | CDLA-60 | 82647 | ![]() | ||||||
4 | 5 | 9 | E | TX | B | CDLA60 | 96214 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | H | U | 1 | Z | EA | 0 | |
DF | SMS | H | U | 1 | N | EA | 0 | |
DM | SMS | H | U | 1 | Z | EA | 0 | |
DN | SMS | H | U | 1 | EA | 0 | ||
DS | SMS | H | U | 1 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPX | Pole Quantity | 1 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 60.0 AMPERES DC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 30.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 900.0 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 NOMINAL AT 200 PCT SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 130.0 SINGLE LOCATION |
CPRQ | Reset Method | AUTOMATIC |
AAQL | Body Style | SINGLE POLE TYPE |
ABHP | Overall Length | 3.156 INCHES NOMINAL |
ADAT | Body Width | 1.875 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.062 INCHES NOMINAL |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.406 INCHES NOMINAL |
AJWX | Mounting Surface To Terminal End Distance | 1.156 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE |
AEBV | Unthreaded Mounting Hole Diameter | 0.250 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 SCREW |
CQXF | Inclosure Protection Type For Which Designed | WEATHERPROOF |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AFJN | Fragility Factor | MODERATELY RUGGED |