| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| G330168-11 | 3 - Design Control Reference | 2 - Production Item | EXELIS INC. | 24930 | |
| UPL1-21430-11 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | SENSATA TECHNOLOGIES MARYLAND, INC | 81541 | |
| AM1A8-5-10 | 5 - Replaced / Discontinued | 2 - Production Item | EATON CORP | 74193 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5925 | 011141846 | A030A0 | 00136 | X | 1 | A | P | U | 13 Jun 1981 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 2 | A | TX | D | G330168-11 | 24930 | | ||||
| 5 | 1 | 4 | 9Z | D | UPL1-21430-11 | 81541 | | |||||
| 1 | 5 | 2 | E | TX | D | AM1A8-5-10 | 74193 | | ||||
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 13 Jun 1981 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZG | P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Germany
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CPRW | Actuator Function | TRIP-RESET |
| CPRX | Actuator Position Designation | AT POLE ONE |
| ADAQ | Body Length | 2.510 INCHES MAXIMUM |
| AAQL | Body Style | SINGLE POLE TYPE |
| ADAT | Body Width | 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
| AJEC | Boss Height | 0.140 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
| AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
| AJWX | Mounting Surface To Terminal End Distance | 2.553 INCHES MAXIMUM |
| CQJX | Nominal Thread Size | 0.138 INCHES |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
| CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| AKPX | Pole Quantity | 1 |
| CPRQ | Reset Method | MANUAL |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 30.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
| BBRJ | Special Handling Feature | MAGNETIC |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| TTQY | Terminal Type And Quantity | 2 THREADED STUD |
| THSD | Thread Series Designator | UNC |
| CMLP | Thread Quantity Per Inch | 32 |