5925-01-131-8480

CIRCUIT BREAKER


5925-01-131-8480 (5925011318480, 011318480)
Part Number (1 listing): AM1-B3-A-15-2
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 18 May 1982

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

Replacement NSN:

5925-00-318-3023

Replacement Date: 4 Dec 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-131-8480 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AM1-B3-A-15-23 - Design Control Reference9 - No Longer UsedEATON CORP  74193    CAGE 74193  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-131-8480 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925011318480A030A000136XKAPA18 May 1982
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

011318480

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-131-8480

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

18 May 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-131-8480 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-131-8480 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
39ETXAM1-B3-A-15-2  74193   CAGE/74193
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-131-8480 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX1BTX04 Dec 1973 5925003183023 3 Dec 1987
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Dec 1973

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5925-00-318-3023

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3 Dec 1987

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-131-8480 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XF

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5925-01-131-8480 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
P1AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXD3DOEQUO
Code Definitions

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-131-8480 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
APNQArc Quenching MethodAIR
ADAQBody Length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
AAQLBody StyleSINGLE POLE TYPE
ADATBody Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AJECBoss Height0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AFJNFragility FactorMODERATELY RUGGED
CPLMMaximum Continuous Load Current Rating Per Pole15.0 AMPERES DC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 DC SINGLE LOCATION
AXHRMounting Facility Type And Quantity2 THREADED HOLE
AJWXMounting Surface To Terminal End Distance2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
CQJXNominal Thread Size0.138 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts65.0 DC SINGLE LOCATION
CQXFInclosure Protection Type For Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 TOGGLE
AKPXPole Quantity1
CPRQReset MethodMANUAL
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CPRJTrip Release MethodMAGNETIC-HYDRAULIC SINGLE LOCATION
CQWNTrip Delay Time In Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 SINGLE LOCATION
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity2 THREADED STUD
THSDThread Series DesignatorUNC
CMLPThread Quantity Per Inch32


Back to Top
Back to Top