5925-01-141-9097

CIRCUIT BREAKER


5925-01-141-9097 (5925011419097, 011419097)
Part Numbers (3 listings): 41-3-S14-LN2-70 | 41-3-S14-LN2-70A | S91-0002-002 |
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 7 Nov 1982

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-141-9097 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
41-3-S14-LN2-703 - Design Control Reference2 - Production ItemOAKLAND INDUSTRIES LTD  06402      
41-3-S14-LN2-70A3 - Design Control Reference2 - Production ItemOAKLAND INDUSTRIES LTD  06402      
S91-0002-0025 - Replaced / Discontinued2 - Production ItemHARRIS CORPORATION  14304    CAGE 14304  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-141-9097 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925011419097A030A000136X1APA7 Nov 1982
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

011419097

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-141-9097

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

7 Nov 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-141-9097 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-141-9097 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETX41-3-S14-LN2-70  06402  
32ETX41-3-S14-LN2-70A  06402  
52ETXS91-0002-002  14304   CAGE/14304
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-141-9097 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59707 Nov 1982
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Nov 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-141-9097 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5925-01-141-9097 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XQQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-141-9097 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE ONE
ADAQBody Length1.260 INCHES NOMINAL
AAQLBody StyleSINGLE POLE TYPE
ADATBody Width0.730 INCHES NOMINAL
ABXDBushing Length0.260 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length0.900 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
AFJNFragility FactorMODERATELY RUGGED
FREQFrequency In Hertz400.0 SINGLE LOCATION
CPLMMaximum Continuous Load Current Rating Per Pole70.0 AMPERES AC SINGLE LOCATION AND 70.0 AMPERES DC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 AC SINGLE LOCATION AND 2000.0 DC SINGLE LOCATION
AXHRMounting Facility Type And Quantity1 THREADED BUSHING W/PANEL SEAL
AJWXMounting Surface To Terminal End Distance2.520 INCHES MAXIMUM
CQJXNominal Thread Size12.0 MILLIMETERS
AEFQNonturn Device Length0.060 INCHES NOMINAL
AEFNNonturn Device LocationAT 12 OCLOCK
AEFPNonturn Device Radius0.370 INCHES NOMINAL
AEFRNonturn Device Width0.110 INCHES NOMINAL
CPRFOperating Voltage Type And Rating Per Pole In Volts115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION
CQXFInclosure Protection Type For Which DesignedCORROSION RESISTANT AND FUNGUS RESISTANT AND HUMIDITY RESISTANT
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 PUSH-PULL
AKPXPole Quantity1
CPRQReset MethodMANUAL
CRCFTrip Release Ambient Temp Rating70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CPRJTrip Release MethodTHERMAL SINGLE LOCATION
CQWNTrip Delay Time In Seconds Per Rated Continuous Current12.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 80.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent140.0 SINGLE LOCATION
PKWTUnpackaged Unit Weight2.300 OUNCES
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity2 TAB W/SCREW
THSDThread Series DesignatorISO M
CQQRThread Pitch In Millimeters1.75


Back to Top
Back to Top