5925-01-193-4304

CIRCUIT BREAKER


5925-01-193-4304 (5925011934304, 011934304)
Part Numbers (3 listings): 2TC27-15/SR12507-66 | 4310-022-15 | HS4844-150 |
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 3 Nov 1984

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.004 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-193-4304 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2TC27-15/SR12507-663 - Design Control Reference2 - Production ItemSENSATA TECHNOLOGIES, INC  82647    CAGE 82647  
4310-022-155 - Replaced / Discontinued2 - Production ItemEATON CORPORATION  76374      
HS4844-1505 - Replaced / Discontinued9 - No Longer UsedMCDONNELL DOUGLAS HELICOPTER CO INC  02731    CAGE 02731  
HS4844-1507 - Vendor Item Drawing Reference2 - Production ItemBOEING COMPANY, THE  8V613    CAGE 8V613  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-193-4304 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925011934304A030A000136X1APA03 Nov 1984
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

011934304

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-193-4304

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

3 Nov 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-193-4304 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Aug 1995
ZH011 Jun 1999
ZN011 Jul 2000
A918A1961CZCTCT1 Nov 2005
ZW011 Mar 2009
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CT

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230

CT

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230


FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-193-4304 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ2TC27-15/SR12507-66  82647   CAGE/82647
525TX4310-022-15  76374  
592CTBHS4844-150  02731   CAGE/02731
721ZZHS4844-150  8V613   CAGE/8V613
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

CT

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-193-4304 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 Nov 1984
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Nov 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-193-4304 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CT658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

CT

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-01-193-4304 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSZU1ZEA0
DSSMSZU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5925-01-193-4304 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX0.1 lbs0.004 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.004 cu ft

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-193-4304 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE ONE
ADAQBody Length0.781 INCHES MAXIMUM
AAQLBody StyleSINGLE POLE TYPE
ADATBody Width0.593 INCHES MAXIMUM
ABXDBushing Length0.470 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length0.500 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
AFJNFragility FactorMODERATELY RUGGED
FREQFrequency In Hertz400.0 SINGLE LOCATION
CPLMMaximum Continuous Load Current Rating Per Pole15.0 AMPERES AC SINGLE LOCATION AND 15.0 AMPERES DC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps2500.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION
AXHRMounting Facility Type And Quantity1 THREADED BUSHING W/PANEL SEAL
AJWXMounting Surface To Terminal End Distance1.343 INCHES MAXIMUM
CQJXNominal Thread Size0.438 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION
CQXFInclosure Protection Type For Which DesignedVIBRATION RESISTANT AND SHOCK RESISTANT AND SANDTIGHT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 PUSH-PULL
AKPXPole Quantity1
CPRQReset MethodMANUAL
CRCFTrip Release Ambient Temp Rating25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CPRJTrip Release MethodTHERMAL SINGLE LOCATION
CQWNTrip Delay Time In Seconds Per Rated Continuous Current15.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 SINGLE LOCATION
PKWTUnpackaged Unit Weight25.0 GRAMS
BBRJSpecial Handling FeatureMAGNETIC
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity2 TAB W/SCREW
THSDThread Series DesignatorUNS
CMLPThread Quantity Per Inch32


Back to Top
Back to Top