5925-01-232-7632

CIRCUIT BREAKER


5925-01-232-7632 (5925012327632, 012327632)
Part Numbers (2 listings): 313C748G25/452D377G07 | ETN530800S36 |
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 20 May 1986

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-232-7632 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
313C748G25/452D377G073 - Design Control Reference2 - Production ItemEATON CORPORATION  89946    CAGE 89946  
ETN530800S365 - Replaced / Discontinued2 - Production ItemSPD ELECTRICAL SYSTEMS, INC  30086    CAGE 30086  
313C748G25/452D377G075 - Replaced / Discontinued9 - No Longer UsedWESTINGHOUSE ELECTRIC CORP  11660    CAGE 11660  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-232-7632 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925012327632A030A000136X1APA20 May 1986
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

012327632

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-232-7632

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

20 May 1986

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-232-7632 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N2H4N9ND1ZVEPSGHGG1 Mar 2005
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

V

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Navy is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

PSDSOR

Depot Source of Repair Codes (DSOR_0903)


Puget Sound Naval Shipyard and Intermediate Maintenance Facility (PSNSY & IMF), Bremerton WA

GHCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-232-7632 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETX313C748G25/452D377G07  89946   CAGE/89946
52ETXETN530800S36  30086   CAGE/30086
59ETXB313C748G25/452D377G07  11660   CAGE/11660
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-232-7632 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597020 May 1986
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 May 1986

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-232-7632 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TXP658Z9AAZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

A

Air Commodity Code (AIR_CMTY_HDLG_9215)


Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-01-232-7632 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNNRPJU1HEA0
Code Definitions

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5925-01-232-7632 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00EAJCXE5DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

EA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-DTL-17667, neutral wrapping paper

JC

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

E5

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, fiberboard box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-232-7632 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT POLE TWO
APNQArc Quenching MethodDEION
ADAQBody Length12.250 INCHES NOMINAL
AAQLBody StyleMULTIPOLE-SINGLE ACTUATOR TYPE
ADATBody Width8.875 INCHES NOMINAL
AJECBoss Height4.813 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length9.875 INCHES NOMINAL
AEBQCenter To Center Distance Between Terminals Parallel To Width3.000 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length9.750 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width3.000 INCHES NOMINAL
CBBLFeatures ProvidedHANDLE LOCK
AFJNFragility FactorMODERATELY RUGGED
FREQFrequency In Hertz60.0 ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps100000.0 AC ALL LOCATIONS
CPLMMaximum Continuous Load Current Rating Per Pole225.0 AMPERES AC ALL LOCATIONS
AXHRMounting Facility Type And Quantity6 THREADED HOLE
CQJXNominal Thread Size0.250 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts500.0 AC ALL LOCATIONS
CQXFInclosure Protection Type For Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT
CPSMInternal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity1 TOGGLE
AKPXPole Quantity3
CPRQReset MethodMANUAL
ABKWOverall Height11.719 INCHES NOMINAL
FEATSpecial FeaturesMOUNTING HARDWARE INCLUDED
THSDThread Series DesignatorUNC
CQWNTrip Delay Time In Seconds Per Rated Continuous Current20.000 MINIMUM AT 200 PCT AND 32.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRLTrip Release CharacteristicTIME DELAY ALL LOCATIONS
CPRJTrip Release MethodMAGNETIC ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent600.0 ALL LOCATIONS
PKWTUnpackaged Unit Weight20.500 POUNDS
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity13 THREADED STUD
CMLPThread Quantity Per Inch20


Back to Top
Back to Top