5925-01-239-4414

CIRCUIT BREAKER


5925-01-239-4414 (5925012394414, 012394414)
Part Number (1 listing): 12MC6-105-50
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 29 Aug 1986

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-239-4414 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
12MC6-105-503 - Design Control Reference2 - Production ItemSENSATA TECHNOLOGIES, INC  82647    CAGE 82647  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-239-4414 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925012394414A030A000136X1APU29 Aug 1986
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

012394414

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-239-4414

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

29 Aug 1986

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-239-4414 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Apr 1991
YB011 Sep 1998
YW011 Nov 1999
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-239-4414 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3249ZD12MC6-105-50  82647   CAGE/82647
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-239-4414 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597029 Aug 1986
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Aug 1986

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-239-4414 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZX
Code Definitions

ZX

Originating Activity Code (ORIG_ACTY_CD_4210)


NAMSA (LI Division)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-239-4414 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT EACH POLE
APNQArc Quenching MethodMAGNETIC BLOWOUT
CPRZAuxiliary Switch Function And Quantity1 ALARM
ADAQBody Length2.270 INCHES NOMINAL
AAQLBody StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADATBody Width1.500 INCHES NOMINAL
AJECBoss Height0.115 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBQCenter To Center Distance Between Terminals Parallel To Width0.750 INCHES NOMINAL
AEBPCenter To Center Distance Between Terminals Parallel To Length1.680 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.063 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 INCHES NOMINAL
CPRYExternal Actuator Linkage ArrangementONE AND TWO LINKED
AFJNFragility FactorMODERATELY RUGGED
FREQFrequency In Hertz60.0 ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 AC ALL LOCATIONS AND 1500.0 DC ALL LOCATIONS
CPLMMaximum Continuous Load Current Rating Per Pole50.0 AMPERES AC ALL LOCATIONS AND 50.0 AMPERES DC ALL LOCATIONS
AXHRMounting Facility Type And Quantity4 THREADED HOLE
AJWXMounting Surface To Terminal End Distance2.510 INCHES NOMINAL
CQJXNominal Thread Size0.138 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts250.0 AC ALL LOCATIONS AND 60.0 DC ALL LOCATIONS
CQXFInclosure Protection Type For Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT
CPSMInternal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity2 TOGGLE
AKPXPole Quantity2
CPRQReset MethodMANUAL
THSDThread Series DesignatorUNC
CQWNTrip Delay Time In Seconds Per Rated Continuous Current0.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 6.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRLTrip Release CharacteristicTIME DELAY ALL LOCATIONS
CPRJTrip Release MethodMAGNETIC ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 ALL LOCATIONS
PKWTUnpackaged Unit Weight8.000 OUNCES
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
CSSXSwitch Current Rating And Type In Amps5.0 AC AND 1.0 DC
CQSMSwitch Location And Position DesignationINTERNAL AT POLE ONE
CRTKSwitch Terminal TypeTAB, SOLDER LUG
CSWPSwitch Voltage Rating And Type In Volts125.0 AC AND 60.0 DC
AEGJSwitch Contact ArrangementSINGLE POLE, DOUBLE THROW
TTQYTerminal Type And Quantity4 THREADED STUD
CMLPThread Quantity Per Inch32


Back to Top