Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
11426-90003 | 3 - Design Control Reference | 2 - Production Item | AAI CORPORATION | 97384 | ![]() |
UPL5111-22195-1 | 5 - Replaced / Discontinued | 2 - Production Item | SENSATA TECHNOLOGIES MARYLAND, INC | 81541 | ![]() |
AM4-A3A3A3A6-A-50-2 | 5 - Replaced / Discontinued | 9 - No Longer Used | EATON CORP | 74193 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 012874283 | A030A0 | 00136 | X | 1 | A | P | A | 22 Oct 1988 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ||||||||||||||||||||||||||||||
DGX1 | 1 | C | TX | 1 Apr 2006 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Columbus, Columbus, OH 43218
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | A | TX | 11426-90003 | 97384 | ![]() | ||||||
5 | 2 | E | TX | UPL5111-22195-1 | 81541 | ![]() | ||||||
5 | 9 | 5 | TX | B | AM4-A3A3A3A6-A-50-2 | 74193 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TH | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43215
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADAQ | Body Length | 2.468 INCHES MINIMUM AND 2.532 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAT | Body Width | 2.968 INCHES MINIMUM AND 3.032 INCHES MAXIMUM |
AJEC | Boss Height | 0.140 INCHES MINIMUM AND 0.172 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.906 INCHES MINIMUM AND 1.970 INCHES MAXIMUM |
CPRH | Circuit Protection Type | OVERCURRENT SECOND LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT THIRD LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT FIRST LOCATION |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.030 INCHES MINIMUM AND 2.094 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
FREQ | Frequency In Hertz | 50.0 FOURTH LOCATION OR 60.0 FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 FIRST LOCATION |
FREQ | Frequency In Hertz | 60.0 SECOND LOCATION |
FREQ | Frequency In Hertz | 60.0 THIRD LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SECOND LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC FIRST LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC THIRD LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC THIRD LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC FIRST LOCATION |
AXHR | Mounting Facility Type And Quantity | 8 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 2.688 INCHES MINIMUM AND 2.752 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SECOND LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC THIRD LOCATION |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPSM | Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
CPSM | Internal Trip Release Configuration | SERIES TRIP SECOND LOCATION |
CPSM | Internal Trip Release Configuration | SERIES TRIP THIRD LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |
AKPX | Pole Quantity | 4 |
CPRQ | Reset Method | MANUAL |
FEAT | Special Features | FOURTH POLE IS SWITCH ONLY |
THSD | Thread Series Designator | UNC |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT FIRST LOCATION AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT SECOND LOCATION AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT THIRD LOCATION AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY FIRST LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SECOND LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY THIRD LOCATION |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC FIRST LOCATION |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SECOND LOCATION |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC THIRD LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 FIRST LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SECOND LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 THIRD LOCATION |
PKWT | Unpackaged Unit Weight | 9.500 OUNCES |
CSSX | Switch Current Rating And Type In Amps | 50.0 AC |
CQSM | Switch Location And Position Designation | EXTERNAL AT POLE FOUR |
CRTK | Switch Terminal Type | THREADED STUD |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
TTQY | Terminal Type And Quantity | 8 THREADED STUD |
CMLP | Thread Quantity Per Inch | 32 |