5925-01-330-7615

CIRCUIT BREAKER


5925-01-330-7615 (5925013307615, 013307615)
Part Number (1 listing): 315C574G29
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 8 Dec 1990

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-330-7615 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
315C574G293 - Design Control Reference2 - Production ItemEATON CORPORATION  89946    CAGE 89946  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-330-7615 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925013307615A030A000136XKAPA8 Dec 1990
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

013307615

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-330-7615

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

8 Dec 1990

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-330-7615 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
C056C1651G1 Jun 2010
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-330-7615 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59708 Dec 1990
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Dec 1990

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-330-7615 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XF

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5925-01-330-7615 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
GPZNCZU1CEA0
Code Definitions

ZNC

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Commanding Officer, USCG Surface Force Logistics Center, Code 028, Mil Stop 25, 2401 Hawkins Point Road, Baltimore, MD 21226-5000

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

C

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions; MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions; NAVY: Field Activity Control Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-330-7615 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length13.000 INCHES NOMINAL
AAQLBody StyleMULTIPOLE-SINGLE ACTUATOR TYPE
ADATBody Width8.250 INCHES NOMINAL
AJECBoss Height0.375 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length9.875 INCHES NOMINAL
AEBQCenter To Center Distance Between Terminals Parallel To Width6.000 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length9.875 INCHES NOMINAL
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width3.000 INCHES NOMINAL
AGAVEnd Item IdentificationUSED ON POWER SUPPLY SYSTEM ONBOARD 378 FT WHEC COAST GUARD VESSELS
FREQFrequency In Hertz400.0 ALL LOCATIONS
CPLMMaximum Continuous Load Current Rating Per Pole160.0 AMPERES AC ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps20000.0 AC ALL LOCATIONS
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
AJWXMounting Surface To Terminal End Distance9.093 INCHES NOMINAL
CPRFOperating Voltage Type And Rating Per Pole In Volts500.0 AC ALL LOCATIONS
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
AKPXPole Quantity3
CPRQReset MethodMANUAL
CRCFTrip Release Ambient Temp Rating50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
CPRLTrip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
CPRJTrip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 ALL LOCATIONS
AEBVUnthreaded Mounting Hole Diameter0.312 INCHES NOMINAL
TTQYTerminal Type And Quantity6 COMPRESSION


Back to Top