Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
CF3-G2G3G3-U-15-240-1 | 3 - Design Control Reference | 9 - No Longer Used | EATON CORP | 74193 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 014652672 | A030A0 | 00136 | X | 1 | A | P | A | A | 0 | 27 May 1999 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Sep 2006 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 9 | 4 | 9Z | D | CF3-G2G3G3-U-15-240-1 | 74193 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 27 May 1999 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC |
Canada
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADAU | Body Height | 2.827 INCHES NOMINAL |
ADAQ | Body Length | 5.844 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAT | Body Width | 3.103 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.026 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 4.750 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 5.032 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 3 SLOT AND 3 THREADED HOLE |
ABTD | Mounting Slot Width | 0.164 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
AKPX | Pole Quantity | 3 |
CPRQ | Reset Method | MANUAL |
THSD | Thread Series Designator | UNC |
CMLP | Thread Quantity Per Inch | 32 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 5.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 5.0 DC |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |