5925-01-493-1723

CIRCUIT BREAKER


5925-01-493-1723 (5925014931723, 014931723)
Part Number (1 listing): APL-111-1-66-102
Summary

FSG 59 / FSC 5925

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 19 Dec 2001

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5925-01-493-1723 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
APL-111-1-66-1023 - Design Control Reference2 - Production ItemSENSATA TECHNOLOGIES MARYLAND, INC  81541    CAGE 81541  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5925-01-493-1723 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595925014931723A030A000136X1APAA019 Dec 2001
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5925

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Circuit Breakers

014931723

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5925-01-493-1723

A030A0

Federal Item Identification Guide (FIIG_4065)

00136

Item Naming Code (INC_4080)

19 Dec 2001

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5925-01-493-1723 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG011 Dec 2001
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5925-01-493-1723 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDAPL-111-1-66-102  81541   CAGE/81541
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5925-01-493-1723 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597019 Dec 2001
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

19 Dec 2001

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5925-01-493-1723 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

DX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5925-01-493-1723 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPRWActuator FunctionTRIP-RESET
CPRXActuator Position DesignationAT EACH POLE
ADAQBody Length2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
AAQLBody StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADATBody Width2.265 INCHES MAXIMUM
AJECBoss Height0.150 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBQCenter To Center Distance Between Terminals Parallel To Width0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
AEBPCenter To Center Distance Between Terminals Parallel To Length1.940 INCHES NOMINAL
CPRHCircuit Protection TypeOVERCURRENT ALL LOCATIONS
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width0.735 INCHES NOMINAL AND 0.765 INCHES MAXIMUM
CPRYExternal Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
FREQFrequency In Hertz50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
CPLMMaximum Continuous Load Current Rating Per Pole1.0 AMPERES AC ALL LOCATIONS
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 AC ALL LOCATIONS
AXHRMounting Facility Type And Quantity6 THREADED HOLE
AJWXMounting Surface To Terminal End Distance2.475 INCHES NOMINAL
CQJXNominal Thread Size0.138 INCHES
CPRFOperating Voltage Type And Rating Per Pole In Volts250.0 AC ALL LOCATIONS
CQXFInclosure Protection Type For Which DesignedMOISTURE RESISTANT AND SALT SPRAY PROOF
CPSMInternal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CPRTManual Actuator Type And Quantity3 TOGGLE
AKPXPole Quantity3
CPRQReset MethodMANUAL
THSDThread Series DesignatorUNC
CMLPThread Quantity Per Inch32
CPRLTrip Release CharacteristicTIME DELAY ALL LOCATIONS
CPRJTrip Release MethodMAGNETIC ALL LOCATIONS
CQWNTrip Delay Time In Seconds Per Rated Continuous Current10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 ALL LOCATIONS
TTQYTerminal Type And Quantity6 THREADED STUD


Back to Top
Back to Top