Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
APL-11-1-61-502-A | 3 - Design Control Reference | 2 - Production Item | SENSATA TECHNOLOGIES MARYLAND, INC | 81541 | ![]() |
MIL-PRF-55629/3D | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5925 | 014947221 | A030A0 | 00136 | X | 1 | A | P | A | A | 0 | 21 Feb 2002 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Feb 2002 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | E | 9Z | D | APL-11-1-61-502-A | 81541 | ![]() | ||||
4 | 4 | 1 | E | 9Z | D | MIL-PRF-55629/3D | 81349 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 21 Feb 2002 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT EACH POLE |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
ADAQ | Body Length | 2.510 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAT | Body Width | 1.500 INCHES NOMINAL |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 2.553 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
AKPX | Pole Quantity | 2 |
CPRQ | Reset Method | MANUAL |
FEAT | Special Features | METRIC THREAD MOUNTING INSERTS AND TERMINALS |
THSD | Thread Series Designator | UNC |
CMLP | Thread Quantity Per Inch | 32 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.135 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
BBRJ | Special Handling Feature | MAGNETIC |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-55629/3D GOVERNMENT SPECIFICATION |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
TEST | Test Data Document | 81349-MIL-PRF-55629/3D SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
AAJE | Thread Pitch Diameters | +0.1177/+0.1214 INCHES |