5930-00-027-2341

SWITCH,SENSITIVE


5930-00-027-2341 (5930000272341, 000272341)
Part Number (1 listing): BZ3RW2T04
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1963

Replacement NSN:

5930-01-040-7155

Replacement Date: 1 Apr 1975

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-027-2341 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
BZ3RW2T043 - Design Control Reference2 - Production ItemHONEYWELL INTERNATIONAL INC.  91929    CAGE 91929  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-027-2341 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930000272341A053A000399X49APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

000272341

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-027-2341

A053A0

Federal Item Identification Guide (FIIG_4065)

00399

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-027-2341 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-027-2341 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
ETX1BTX01 Apr 1975 5930010407155 25 Apr 1968
Code Definitions

E

Item Standardization Code (ISC_2650)


An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Apr 1975

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5930-01-040-7155

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

25 Apr 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-027-2341 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-027-2341 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFUUActuator Free Position Height1.026 INCHES NOMINAL
AFGKActuator Length1.900 INCHES NOMINAL
AFUVActuator Roller Diameter0.370 INCHES NOMINAL
AFUWActuator Roller Width0.150 INCHES NOMINAL
AFUQActuator StyleROLLER ARM
ADAUBody Height1.150 INCHES NOMINAL
ADAQBody Length1.940 INCHES NOMINAL
AAQLBody StyleHOLE MOUNTED
ADATBody Width0.687 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.000 INCHES NOMINAL
CXQRContact Load Current Rating At Maximum Rated Voltage15.000 AMPERES RESISTIVE DC AND 50.000 MILLIAMPERES INDUCTIVE DC AND 300.000 MILLIAMPERES LAMP DC AND 2.000 AMPERES RESISTIVE AC AND 0.500 AMPERES LAMP AC AND 2.000 AMPERES MOTOR AC
CBBLFeatures ProvidedACTUATOR SEAL
ABFEHazardous Locations/Environmental ProtectionDUSTPROOF
AFXEMaximum Voltage Rating In Volts600.0 AC AND 250.0 DC
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
AKNAInclosure TypeFULLY INCLOSED
AEBVUnthreaded Mounting Hole Diameter0.140 INCHES NOMINAL
CRRMSwitch Release Force0.7 OUNCES NOMINAL
CSJNSwitch Actuating Force1.0 OUNCES MINIMUM AND 4.5 OUNCES MAXIMUM
TTQYTerminal Type And Quantity3 SCREW


Back to Top
Back to Top