Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
DA21-127 | 3 - Design Control Reference | 1 - Incomplete Part Number | MERCOID CORP THE | 39709 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 000754685 | A048B0 | 00206 | X | 4 | 9 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G900 | 0 | 0 | L | 1 Apr 1991 |
Not Established
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 3 Feb 1971 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQGB | Contact Action Stimulus | INCREASE |
CTYC | Contact Adjustability | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | Contact Adjustment Range | +0.00 TO 60.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.00 TO 60.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CTHF | Contact Load Current Rating | 10.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | Contact Load Current Rating | 10.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | Contact Load Current Rating | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | Contact Load Current Rating | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 230.0 DC AT SEA LEVEL SECOND VOLTAGE |
AXGY | Mounting Method | BRACKET |
CRLD | Nonpile-Up Contact Arrangement | 2 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
STYL | Style Designator | CYLINDRICAL W/PORT |
AJZC | Pressure Switch Type | DIFFERENTIAL |
ABKW | Overall Height | 2.125 INCHES NOMINAL |
ABHP | Overall Length | 7.250 INCHES NOMINAL |
ABMK | Overall Width | 5.750 INCHES NOMINAL |
FEAT | Special Features | WITH TILTING TYPE MERCURY SWITCH |
ASDB | Width Across Flats | 0.563 INCHES NOMINAL |
CSCF | Terminal Type | WIRE LEAD |