5930-00-088-9327

SWITCH,SENSITIVE


5930-00-088-9327 (5930000889327, 000889327)
Part Numbers (5 listings): MS25253-4 | MIL-S-6743 | 441162 | 2706-0 | 994-1200 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Replacement NSN:

5930-00-683-2814

Replacement Date: 31 Mar 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-088-9327 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MS25253-42 - Definitive Specification or Standard Document2 - Production ItemMILITARY STANDARDS  96906    CAGE 96906  
MIL-S-67434 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
441162C - Advisory Reference1 - Incomplete Part NumberINTERNATIONAL BUSINESS MACHINES CORP  30874    CAGE 30874  
441162C - Advisory Reference1 - Incomplete Part NumberINTERNATIONAL BUSINESS MACHINES CORP  30874    CAGE 30874  
441162C - Advisory Reference1 - Incomplete Part NumberINTERNATIONAL BUSINESS MACHINES CORP  30874    CAGE 30874  
441162C - Advisory Reference1 - Incomplete Part NumberINTERNATIONAL BUSINESS MACHINES CORP  30874    CAGE 30874  
441162C - Advisory Reference1 - Incomplete Part NumberINTERNATIONAL BUSINESS MACHINES CORP  30874    CAGE 30874  
2706-0C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
2706-0C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
2706-0C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
2706-0C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
2706-0C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
994-1200C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
994-1200C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
994-1200C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
994-1200C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
994-1200C - Advisory Reference1 - Incomplete Part NumberA L D INC  05789    CAGE 05789  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-088-9327 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930000889327A053A000399X49APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

000889327

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-088-9327

A053A0

Federal Item Identification Guide (FIIG_4065)

00399

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-088-9327 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YD011 Apr 1991
YJ011 Apr 1991
ZA011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZK011 Apr 1991
ZP011 Apr 1991
ZS011 Apr 1991
ZR011 Jul 1997
YW011 Aug 1997
YA011 Dec 1999
ZW011 Aug 2002
YY011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-088-9327 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3223TXDMS25253-4  96906   CAGE/96906
413TXMIL-S-6743  81349   CAGE/81349
C15TXLZ2706-0  05789   CAGE/05789
C15TXLZ994-1200  05789   CAGE/05789
C15TXLZ441162  30874   CAGE/30874
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

LZ

Service / Agency Designator Code (SADC_4672)


Army / Air Force / Navy / Defense Logistics Agency / Other Civil Agencies


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-088-9327 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX031 Mar 1975 5930006832814 17 Mar 1969
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

31 Mar 1975

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5930-00-683-2814

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

17 Mar 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-088-9327 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-00-088-9327 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU0EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-088-9327 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFUUActuator Free Position Height0.625 INCHES MAXIMUM
AFUSActuator Height0.109 INCHES NOMINAL
CXQQActuator Movement0.046 PRETRAVEL INCHES MAXIMUM AND 0.031 OVERTRAVEL INCHES MINIMUM AND 0.020 DIFFERENTIAL INCHES MAXIMUM
AFGKActuator Length0.110 INCHES NOMINAL
AFUQActuator StyleRECTANGULAR
AFUTActuator Width0.165 INCHES NOMINAL
ADAUBody Height0.625 INCHES NOMINAL
ADAQBody Length1.094 INCHES NOMINAL
AAQLBody StyleHOLE MOUNTED
ADATBody Width0.415 INCHES MAXIMUM
ADTVCase MaterialPLASTIC
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.406 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length0.875 INCHES NOMINAL
CXQRContact Load Current Rating At Maximum Rated Voltage10.000 AMPERES RESISTIVE DC AND 6.000 AMPERES INDUCTIVE DC AND 6.000 AMPERES MOTOR DC AND 10.000 AMPERES RESISTIVE AC AND 10.000 AMPERES INDUCTIVE AC AND 6.000 AMPERES MOTOR AC
AFXEMaximum Voltage Rating In Volts115.0 AC AND 28.0 DC
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT
AKNAInclosure TypeFULLY INCLOSED
ABKWOverall Height0.875 INCHES NOMINAL
ABHPOverall Length1.375 INCHES NOMINAL
ABMKOverall Width0.415 INCHES MAXIMUM
AEBVUnthreaded Mounting Hole Diameter0.114 INCHES NOMINAL
ZZZKSpecification/Standard Data96906-MS25253 GOVERNMENT STANDARD
CSJNSwitch Actuating Force14.0 OUNCES MAXIMUM
TTQYTerminal Type And Quantity3 TAB W/SCREW
TESTTest Data Document81349-MIL-S-6743 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top