5930-00-136-1856

SWITCH,ROTARY


5930-00-136-1856 (5930001361856, 001361856)
Part Number (1 listing): 42M36-01-1-3N
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 13 Jan 1969

Replacement NSN:

5930-00-433-6089

Replacement Date: 24 Nov 1970

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-136-1856 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
42M36-01-1-3N3 - Design Control Reference2 - Production ItemGRAYHILL, INC  81073    CAGE 81073  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-136-1856 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930001361856A052B002134X1APS13 Jan 1969
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

001361856

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-136-1856

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

13 Jan 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-136-1856 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-136-1856 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3323TXD42M36-01-1-3N  81073   CAGE/81073
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-136-1856 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX024 Nov 1970 5930004336089 4 Feb 1973
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Nov 1970

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5930-00-433-6089

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

4 Feb 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-136-1856 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-00-136-1856 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU0EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-136-1856 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating20.0 MILLIAMPERES RESISTIVE LOAD AC AT ALTITUDE
CTHFContact Load Current Rating200.0 MILLIAMPERES RESISTIVE LOAD DC AT ALTITUDE AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT ALTITUDE
CTHFContact Load Current Rating75.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL
CTHFContact Load Current Rating250.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 100.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CQMKContact Voltage Rating In Volts28.0 DC AT ALTITUDE
CQMKContact Voltage Rating In Volts28.0 DC AT SEA LEVEL
CSHWContact Switching ActionBREAKS BEFORE MAKES SINGLE SECTION REAR
CQMKContact Voltage Rating In Volts115.0 AC AT ALTITUDE
CQMKContact Voltage Rating In Volts115.0 AC AT SEA LEVEL
ABNBFirst Flat Length0.250 INCHES NOMINAL SINGLE ACTUATOR
ABNCFlat Height0.219 INCHES NOMINAL SINGLE ACTUATOR
ABFEHazardous Locations/Environmental ProtectionEXPLOSION PROOF
AXGYMounting MethodTHREADED BUSHING SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.375 INCHES SINGLE MOUNTING FACILITY
AEFPNonturn Device Radius0.375 INCHES NOMINAL AT 3:00 O'CLOCK
AFDCNonturn Device TypeTAB AT 3:00 O'CLOCK
AFGAOperating Temp Range-65.0/+85.0 DEG CELSIUS
ADAVOverall Diameter1.015 INCHES NOMINAL
AFBHIndividual Section Quantity1
AKPXPole Quantity1 SINGLE SECTION FRONT
PMLCPrecious Material And LocationCONTACTS AND TERMINAL SURFACES SILVER
PRMTPrecious MaterialSILVER
CQTHRotor Through Connection Quantity1 SINGLE SECTION
CQRQShaft Flat/Slot Angular Location36.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR
ABXFShaft Length0.437 INCHES NOMINAL SINGLE ACTUATOR
ABWVShaft Diameter0.250 INCHES NOMINAL SINGLE ACTUATOR
CRSJShaft TypeROUND, FLATTED SINGLE ACTUATOR
ABHPOverall Length1.899 INCHES NOMINAL
STYLStyle DesignatorTAP, CIRCULAR, BUSHING MOUNT
CRJHSwitch Actuator Indexing Position Quantity3 SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment36.0 DEGREES SINGLE ACTUATOR
CTDNSwitch Actuator Stop Device TypeFIXED STOP SINGLE ACTUATOR
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB, SOLDER LUG
AAJDThread Class2A SINGLE MOUNTING FACILITY
AASAThread Length0.437 INCHES NOMINAL SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNEF SINGLE MOUNTING FACILITY
AKPYThrow Quantity3 SINGLE SECTION REAR


Back to Top
Back to Top