Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
C77-2010-4CC2-4610 | 3 - Design Control Reference | 2 - Production Item | SPD ELECTRICAL SYSTEMS, INC | 30086 | ![]() |
C77-2010-4CC2-4610 | 5 - Replaced / Discontinued | 9 - No Longer Used | BROWN BOVERI ELECTRIC INC | 63159 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 001663406 | A052B0 | 02134 | X | 4 | 6 | A | P | U | 12 Nov 1971 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ||||||||||||||||||||||||||||||
N9BN | 5 | L | Z | GH | HD | 1 Nov 2005 |
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 5 | TX | D | C77-2010-4CC2-4610 | 30086 | ![]() | ||||
5 | 9 | 6 | TX | C77-2010-4CC2-4610 | 63159 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 10.0 AMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL AND 8.0 AMPERES INDUCTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 8.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL AND 6.0 AMPERES INDUCTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 250.0 MILLIAMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL AND 250.0 MILLIAMPERES INDUCTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 40.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL AND 24.0 AMPERES INDUCTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 550.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 600.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 115.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 24.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CBBL | Features Provided | ACTUATOR KNOB |
CQYJ | Mounting Facility Pattern | FOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.164 INCHES SINGLE MOUNTING FACILITY |
AFDV | Longest Vertical Distance Between Mounting Centers | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFDS | Longest Horizontal Distance Between Mounting Centers | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
STYL | Style Designator | TAP, SQUARE FRAME |
CRJH | Switch Actuator Indexing Position Quantity | 3 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 45.0 DEGREES SINGLE ACTUATOR |
CMLP | Thread Quantity Per Inch | 32 SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNC SINGLE MOUNTING FACILITY |