Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
59643RH3 | 3 - Design Control Reference | 2 - Production Item | ELECTRO SWITCH CORP. | 76854 | ![]() |
SMC134943 | 5 - Replaced / Discontinued | 2 - Production Item | US ARMY COMMUNICATIONS & | 80063 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 002196877 | A052B0 | 02134 | X | M | 9 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Mar 1999 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 7 Jul 1968 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQMK | Contact Voltage Rating In Volts | 250.0 AC AT ALTITUDE |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES EACH SECTION FRONT |
ABNB | First Flat Length | 0.314 INCHES MINIMUM SINGLE ACTUATOR AND 0.336 INCHES MAXIMUM SINGLE ACTUATOR |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AEFP | Nonturn Device Radius | 0.526 INCHES MINIMUM AT 9:00 O'CLOCK AND 0.536 INCHES MAXIMUM AT 9:00 O'CLOCK |
AFDC | Nonturn Device Type | TAB AT 9:00 O'CLOCK |
AFGA | Operating Temp Range | -40.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 3 |
AKPX | Pole Quantity | 1 1ST SECTION REAR |
AKPX | Pole Quantity | 1 2ND SECTION REAR |
AKPX | Pole Quantity | 1 3RD SECTION FRONT |
CQTH | Rotor Through Connection Quantity | 2 EACH SECTION |
ABWV | Shaft Diameter | 0.248 INCHES MINIMUM SINGLE ACTUATOR AND 0.252 INCHES MAXIMUM SINGLE ACTUATOR |
CQRQ | Shaft Flat/Slot Angular Location | 90.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
ABXF | Shaft Length | 0.594 INCHES MINIMUM SINGLE ACTUATOR AND 0.656 INCHES MAXIMUM SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, PARALLEL FLATTED, THREADED HOLE SINGLE ACTUATOR |
ADAV | Overall Diameter | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
ABHP | Overall Length | 2.434 INCHES MINIMUM AND 2.496 INCHES MAXIMUM |
AATB | Width Between Flats | 0.184 INCHES MINIMUM SINGLE ACTUATOR AND 0.188 INCHES MAXIMUM SINGLE ACTUATOR |
STYL | Style Designator | CIRCULAR WAFER, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 20 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 18.0 DEGREES SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
TEST | Test Data Document | 80063-SM-C-134943 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
AASA | Thread Length | 0.234 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |
AKPY | Throw Quantity | 20 1ST SECTION FRONT |
AKPY | Throw Quantity | 20 2ND SECTION FRONT |
AKPY | Throw Quantity | 5 3RD SECTION FRONT |