Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
SC-C-38066 | 3 - Design Control Reference | 2 - Production Item | US ARMY COMMUNICATIONS & | 80063 | ![]() |
12-219C | 5 - Replaced / Discontinued | 2 - Production Item | ELECTRO SWITCH CORP. | 76854 | ![]() |
12-219C | 5 - Replaced / Discontinued | 9 - No Longer Used | ESPEY MFG. & ELECTRONICS CORP. | 20950 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 002555898 | A052B0 | 02134 | X | 4 | 3 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 1 | TX | D | SC-C-38066 | 80063 | ![]() | ||||
1 | 5 | 2 | 5 | TX | D | 12-219C | 76854 | ![]() | ||||
1 | 5 | 9 | 5 | TX | B | 12-219C | 20950 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 7 Jul 1968 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FF | 658 | Z | 2 | A | H | Y | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Code FF denotes special factors or conditions in an item description which have an effect on the ratings or charges; therefore, the item description should be read carefully to ensure that such special factors or conditions can be included as a part of the bill of lading description.
Electical Appliances, Small
No special type of cargo code applicable
Classified
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 1.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 500.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 28.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 110.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
ABNB | First Flat Length | 0.484 INCHES MINIMUM SINGLE ACTUATOR AND 0.516 INCHES MAXIMUM SINGLE ACTUATOR |
ABNC | Flat Height | 0.214 INCHES MINIMUM SINGLE ACTUATOR AND 0.224 INCHES MAXIMUM SINGLE ACTUATOR |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 2 |
AKPX | Pole Quantity | 1 1ST SECTION FRONT |
AKPX | Pole Quantity | 1 1ST SECTION REAR |
AKPX | Pole Quantity | 1 2ND SECTION FRONT |
ABWV | Shaft Diameter | 0.243 INCHES MINIMUM SINGLE ACTUATOR AND 0.253 INCHES MAXIMUM SINGLE ACTUATOR |
CQRQ | Shaft Flat/Slot Angular Location | 22.5 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, FLATTED SINGLE ACTUATOR |
ABXF | Shaft Length | 5.046 INCHES MINIMUM SINGLE ACTUATOR AND 5.078 INCHES MAXIMUM SINGLE ACTUATOR |
ABHP | Overall Length | 6.546 INCHES MINIMUM AND 6.578 INCHES MAXIMUM |
STYL | Style Designator | CIRCULAR WAFER, BUSHING MOUNT |
CSLC | Switch Actuator Positioning Increment | 30.0 DEGREES SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
AASA | Thread Length | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |
AKPY | Throw Quantity | 5 1ST SECTION FRONT |
AKPY | Throw Quantity | 5 1ST SECTION REAR |
AKPY | Throw Quantity | 5 2ND SECTION FRONT |