5930-00-296-9101

SWITCH,SENSITIVE


5930-00-296-9101 (5930002969101, 002969101)
Part Numbers (24 listings): 679551 | 31149-100PC840 | 31149-1000PC840 | 31149-1100PC840 | 31149-200PC840 | 31149-5200PC840 | 31149-800PC840 | 31149-840 | 31149-840PC840 | 36A6020-1 | 451958 | K56J735REV2 | CR1070C103B3 | 2409-965509ALTEPC840 | 2409-965590PC840 | 2409-965555ALTEPC840 | 2409-965558PC840 | 2409-965549ALTDPC840 | 2409-965533ALTDPC840 | 2409-965503ALTGPC840 | CR1070C146B3 | 60294 | 319211PC15 | 81386 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Unit Weight: 3.0 lbs

Unit Size: None

Unit Pack Cube: None

Replacement NSN:

5930-00-503-3850

Replacement Date: 6 May 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-296-9101 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
6795513 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
31149-100PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-1000PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-1100PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-200PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-5200PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-800PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
31149-840PC8403 - Design Control Reference2 - Production ItemBAUSCH & LOMB INC  06175      
36A6020-13 - Design Control Reference2 - Production ItemNAVCOM DEFENSE ELECTRONICS, INC.  57057    CAGE 57057  
4519583 - Design Control Reference2 - Production ItemHONEYWELL INTERNATIONAL INC.  59364    CAGE 59364  
K56J735REV23 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
CR1070C103B33 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
2409-965509ALTEPC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2409-965590PC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2409-965555ALTEPC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2409-965558PC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2409-965549ALTDPC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2409-965533ALTDPC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
2409-965503ALTGPC8403 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
CR1070C146B35 - Replaced / Discontinued2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
602945 - Replaced / Discontinued2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
319211PC155 - Replaced / Discontinued2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
813865 - Replaced / Discontinued9 - No Longer UsedCOOPER INDUSTRIES INC  04009      
4519585 - Replaced / Discontinued9 - No Longer UsedALLIED-SIGNAL INC  77068    CAGE 77068  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-296-9101 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930002969101A053A000399X1APS1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

002969101

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-296-9101

A053A0

Federal Item Identification Guide (FIIG_4065)

00399

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-296-9101 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZC011 Apr 1991
ZH011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
ZR011 Jul 1997
ZW011 Nov 1998
YA011 Jan 2002
YY011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-296-9101 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325TX36A6020-1  57057   CAGE/57057
325ZZ451958  59364   CAGE/59364
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-296-9101 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX06 May 1969 5930005033850 17 May 1968
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 May 1969

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5930-00-503-3850

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

17 May 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-296-9101 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-00-296-9101 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU1EA0
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5930-00-296-9101 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA3.0 lbs
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000000D1D100QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

3.0 lbs

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-296-9101 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFUSActuator Height0.094 INCHES NOMINAL
AFURActuator Diameter0.125 INCHES NOMINAL
AFUUActuator Free Position Height0.500 INCHES NOMINAL
CXQQActuator Movement0.059 PRETRAVEL INCHES MAXIMUM AND 0.010 OVERTRAVEL INCHES MINIMUM AND 0.020 DIFFERENTIAL INCHES NOMINAL
AFUQActuator StyleROUND
ADAUBody Height0.500 INCHES NOMINAL
ADAQBody Length1.250 INCHES NOMINAL
AAQLBody StyleHOLE MOUNTED
ADATBody Width0.500 INCHES NOMINAL
ADTVCase MaterialPLASTIC
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.312 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length0.520 INCHES NOMINAL
CXQRContact Load Current Rating At Maximum Rated Voltage300.000 MILLIAMPERES RESISTIVE DC AND 10.000 AMPERES RESISTIVE AC
AFXEMaximum Voltage Rating In Volts115.0 AC AND 115.0 DC
AXGYMounting MethodTHREADED HOLE
CRLDNonpile-Up Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION SINGLE SWITCH UNIT
AKNAInclosure TypeFULLY INCLOSED
PMLCPrecious Material And LocationTERMINAL SURFACES SILVER
ABKWOverall Height0.594 INCHES NOMINAL
ABHPOverall Length1.750 INCHES NOMINAL
ABMKOverall Width0.500 INCHES NOMINAL
AEBVUnthreaded Mounting Hole Diameter0.094 INCHES NOMINAL
CRRMSwitch Release Force3.0 OUNCES MINIMUM
CSJNSwitch Actuating Force20.0 OUNCES MAXIMUM
TTQYTerminal Type And Quantity2 TAB, SOLDER LUG