Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
974707-3B | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 82577 | ![]() |
12166 | 5 - Replaced / Discontinued | 2 - Production Item | HYDRA-ELECTRIC COMPANY | 98505 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 003376283 | A048B0 | 00206 | X | 1 | A | P | U | 28 Dec 1973 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE | ||||||||||||||||||||||||||||||
ZE01 | 1 Jun 1999 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | TX | D | 974707-3B | 82577 | ![]() | ||||
3 | 5 | 2 | 5 | TX | D | 12166 | 98505 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAQ | Body Length | 1.000 INCHES MAXIMUM |
CQGB | Contact Action Stimulus | INCREASE |
CTYC | Contact Adjustability | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTHF | Contact Load Current Rating | 3.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CTYX | Contact Stimulus Rating | 2.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE |
CTZB | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
MEDA | Media For Which Designed | GAS |
AXGY | Mounting Method | INLET CONNECTION |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE PRESSURE CONNECTION |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AWTN | Operating Temp Rating | -55.0 DEG FAHRENHEIT MINIMUM AND 204.0 DEG FAHRENHEIT MAXIMUM |
ABKV | Outside Diameter | 0.375 INCHES NOMINAL SINGLE CONNECTION |
STYL | Style Designator | CYLINDRICAL |
CTZL | Pressure Connector Type | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
AJZC | Pressure Switch Type | ABSOLUTE |
CQJB | Proof Pressure | 60.00 POUNDS PER SQUARE INCH ABSOLUTE |
ADAV | Overall Diameter | 1.230 INCHES MAXIMUM |
ABHP | Overall Length | 1.549 INCHES MAXIMUM |
CSCF | Terminal Type | TURRET |
AAJD | Thread Class | 3A SINGLE PRESSURE CONNECTION |
AASA | Thread Length | 0.239 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
CMLP | Thread Quantity Per Inch | 24 SINGLE PRESSURE CONNECTION |
THSD | Thread Series Designator | UNF SINGLE PRESSURE CONNECTION |