Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
10558401 | 3 - Design Control Reference | 2 - Production Item | US ARMY ARDEC RDECOM | 19200 | ![]() |
199313 | 5 - Replaced / Discontinued | 2 - Production Item | TRANSICO INC. | 97525 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 006175048 | A052B0 | 62415 | X | 1 | A | P | G | 17 Oct 1969 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains gold.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
DGX1 | DTX1 | 3 | H | TX | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Columbus, Columbus, OH 43218
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 1 | TX | D | 10558401 | 19200 | ![]() | ||||
1 | 5 | 2 | 5 | BF | D | 199313 | 97525 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 17 Feb 1971 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
No QUP
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
1
Department of the Army
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AYDW | Actuator Type | THUMBWHEEL ALL ACTUATORS |
HUES | Color | BLACK EACH INDICATOR BACKGROUND |
HUES | Color | WHITE EACH INDICATOR MARKING |
HUES | Color | NATURAL EACH LAMP |
CTZT | Contact Arrangement Truth Table | DECIMAL, 1 POLE - 10 POSITIONS 2ND SECTION |
CTZT | Contact Arrangement Truth Table | DECIMAL, 1 POLE - 10 POSITIONS 3RD SECTION |
CTZT | Contact Arrangement Truth Table | DECIMAL, 1 POLE - 10 POSITIONS 4TH SECTION |
CTZT | Contact Arrangement Truth Table | DECIMAL, 1 POLE - 10 POSITIONS 5TH SECTION |
CTZT | Contact Arrangement Truth Table | DECIMAL, 1 POLE - 10 POSITIONS 6TH SECTION |
CTZT | Contact Arrangement Truth Table | DECIMAL, 1 POLE - 10 POSITIONS 7TH SECTION |
CTZT | Contact Arrangement Truth Table | DECIMAL, 2 POLE - 10 POSITIONS 1ST SECTION |
CTHF | Contact Load Current Rating | 125.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL |
CBBL | Features Provided | ILLUMINATED AND LEGEND PLATE |
ABFE | Hazardous Locations/Environmental Protection | EXPLOSION RESISTANT |
CQYJ | Mounting Facility Pattern | FOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY |
AXGY | Mounting Method | FLANGE SINGLE MOUNTING FACILITY AND UNTHREADED HOLE SINGLE MOUNTING FACILITY |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
STYL | Style Designator | RECTANGULAR INLINE INDICATING |
AFBH | Individual Section Quantity | 7 |
AFDS | Longest Horizontal Distance Between Mounting Centers | 3.490 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 3.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AFDV | Longest Vertical Distance Between Mounting Centers | 1.933 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.943 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
PRMT | Precious Material | GOLD |
PMLC | Precious Material And Location | PRINTED CIRCUIT BOARD CIRCUIT SURFACES GOLD |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5 1ST SECTION |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9 2ND SECTION |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9 3RD SECTION |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9 4TH SECTION |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9 5TH SECTION |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9 6TH SECTION |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9 7TH SECTION |
ABKW | Overall Height | 2.476 INCHES MINIMUM AND 2.496 INCHES MAXIMUM |
ABHP | Overall Length | 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM |
ABMK | Overall Width | 2.200 INCHES MAXIMUM |
FEAT | Special Features | STOP PROVIDED TO LIMIT ACTUATOR ROTATION ON FIRST SECTION |
AEBV | Unthreaded Mounting Hole Diameter | 0.125 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.172 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CRJH | Switch Actuator Indexing Position Quantity | 10 2ND ACTUATOR |
CRJH | Switch Actuator Indexing Position Quantity | 10 3RD ACTUATOR |
CRJH | Switch Actuator Indexing Position Quantity | 10 4TH ACTUATOR |
CRJH | Switch Actuator Indexing Position Quantity | 10 5TH ACTUATOR |
CRJH | Switch Actuator Indexing Position Quantity | 10 6TH ACTUATOR |
CRJH | Switch Actuator Indexing Position Quantity | 10 7TH ACTUATOR |
CRJH | Switch Actuator Indexing Position Quantity | 6 1ST ACTUATOR |
CSCF | Terminal Type | PRINTED CIRCUIT |